background image

3

5

Mark post to post centres using appropriate markings such as spray paint or stakes. Standard fence panel post centres are at 2450mm. If using shorter spans, space 
posts appropriately.
Posts are 102x102mm square.

Mark post positions with spray 
paint or appropriate markers

Standard post spacing

2450mm C of posts

2450mm C of posts

2450mm C of posts

For FENCE POSTS:
Set posts into ground ensuring appropriate gap at bottom (refer Step 2). Pour in concrete. For end posts use 1 way post, for in-line posts use 2 way and for corners use 
90° posts.
Use a soft mallet with a wooden block on the top of the fence posts to drive the post into the wet concrete to the desired height, aligning with both top and bottom string 
lines. If not using top string line, assess height of posts in a line by eye (illustrate). 
Check posts plumb using a spirit level and adjust as necessary.
Allow concrete to set before installing panels.

Drop posts into dug-out 
holes. Posts are pre-notched 
for top and bottom rails.

Use a soft mallet to finish posts 
height, aligning top of post with 
string-line, observing slot height 
with bottom string-line. Use a 
spirit level to plumb posts.

If not using a top string-line, align tops of posts by observing 
imaginary straight line across top edges of posts in a row.

Level 
to other 
posts.

Align bottom of post slot 
hole with string-line

Pour in concrete

For GATE POSTS ONLY: 
Gate posts sold with aluminium inserts for rigidity. Use gate posts for both hinge and latch sides of gate. Pay attention to orientation of slots on post, ensuring rail slots 
face away from the gate opening.
Plumb using a spirit level and adjust height and angle as necessary before concrete cures.

min

300mm

min

300mm

1/3rd

2/3rds

INTERIOR OF FENCE

EXTERIOR OF FENCE

600mm minimum 

deep

4

For in-ground installation dig holes for posts minimum 600mm deep by 300x300mm wide. 
Hole positioning should be dug so that posts can be inserted against string-line by digging the holes approximately 2/3rds inside the string-line. Refer above right image.
Holes for posts should be minimum 600mm deep.
If using base plated posts ignore above step and refer next page.

6

S E M I   P R I V A C Y   F E N C I N G  

I N S T A L L   G U I D E

 — hamptons fencing

91

Summary of Contents for HF-SEMIP-DC

Page 1: ...t finishing White UV stabilised PVC with protective titanium dioxide additives Use silicone for long term binding Slimline tapered cap Order Code HF SEMIP STC 107mm 36mm 107mm TECH SPECS 2 part domical cover suits 102x102mm post Can fitted after post and panels installed 2 parts neatly clip together White UV stabilised PVC with protective titanium dioxide additives Provides a stylish post finish 2...

Page 2: ...ide of bottom rail Assess layout of fence and set out string line around outside perimeter of fence The string must be positioned along the outside perimeter of your posts Ensure allowance made for digging post holes and concreting within your property boundaries and to avoid utility lines Set the height of the string line to the desired height of the underside of the bottom fence rail A gap under...

Page 3: ...o finish posts height aligning top of post with string line observing slot height with bottom string line Use a spirit level to plumb posts If not using a top string line align tops of posts by observing imaginary straight line across top edges of posts in a row Level to other posts Align bottom of post slot hole with string line Pour in concrete For GATE POSTS ONLY Gate posts sold with aluminium ...

Page 4: ...ing appropriate tek screws not supplied at approximately 15mm from ground level Ensure tek screws engage into the base plates Use 6 screws total 2 on slotted side 2 on solid side and 1 on each wing Ensure tek screws do not clash D Install 2 part domical cover at bottom of post to hide screws Domical cover height is 37mm If domical cover required minimum distance under slot must be 40mm Top and bot...

Page 5: ...subsequent step The long pickets are postitioned 6 pickets in from either end 9 Insert long pickets through mid rail and into bottom rail NOTE If panels width adjusted and therefore horizontal rail widths adjusted you may need to cut suitable holes through mid rail and on underside of top rail to allow for longer pickets to pass through As standard the longer pickets are evenly spaced from either ...

Page 6: ...ld recess into each post approx 20mm If using custom span lengths secure top rail inside post with appropriate screws if not re notching with tool Repeat process for remaining posts Apply silicone to inner of top caps and press on to each post to finish 12 Install top rail over long pickets guiding pickets into holes on underside of top rail Insert top rail into one post and then lever into adjace...