Operation
3.
NOTE: Use only compatible solvents and materials or the seals and O-rings will
be damaged.
The sections that follow are in the recommended order to operate the jet valve. Do the
sub-sections in Section 3, in the order shown.
NOTE: The jet valve is shown removed from the workcell in the procedures
below. It is not necessary to remove the jet valve to do the procedures.
Install the Diaphragm
3.1
1.
Set the jet valve to open with the operator interface of JDX controller box.
2.
Align the ribs on top of the diaphragm to the groove features on the bottom of
the heater block.
Figure 2: Diaphragm and Heater Block Grooves
3.
Put the diaphragm on your finger tip and gently press it into heater block with
metal insert aligned with the center hole.
Figure 3: Diaphragm Installed in the Heater Block
Grooves on the