FC100-CF Manual
Revision B
/
February 2022
Page 6 of 23
Nozzle Options
The FC100-CF valve is available with a variety of film coat nozzles. All nozzles have a
different orifice to allow for a maximum flow rate and a slit to create a fan shaped flow
pattern. The width of the fan pattern is determined by the distance from the valve nozzle
to the substrate. Different nozzles are easily interchangeable to the valve by removing the
nozzle cap (
Nozzle sizes are selected based on the viscosity of the coating fluid and desired coating
thickness. PVA’s application engineers can help you select the best nozzle for your valve.
Valves are supplied from the factory with one nozzle included.
Below is a chart showing the part numbers that are used to specify the nozzle that is
supplied with a valve and the available orifices, flow rates, and fan widths, for each
individual nozzle.
Nozzle Part Number
Flow Rate
Fan Width
P1150013-A
0.05 gpm @ 500psi.
8.0-9.99 mm @ 0.5 in distance
P1150013-B
0.05 gpm @ 500psi.
10.0-10.99 mm @ 0.5 in distance
P1150013-C
0.05 gpm @ 500psi.
11.0-12.50 mm @ 0.5 in distance
Figure 1: Nozzle Options