![PVA B12-1686 Operation Manual Download Page 3](http://html.mh-extra.com/html/pva/b12-1686/b12-1686_operation-manual_1628562003.webp)
Safety
Due to material contents being under pressure eye protection is required for
operators. Refer to MSDS sheets on material being dispensed for other precautions.
Setup
The FC100 requires a 2-position, 4-way air solenoid valve to actuate the air
section. The valve should be operated with clean, dry air between 60-100psi. Two #10-32
threaded air ports are located on the air section of the valve. The port located furthest
from the midsection of the valve is air to close the valve. The port located closest to the
mid-section of the valve is air to open the valve. Quick connect air fittings are typically
supplied with the FC100 to fit 5/32” tubing. Note that the valve should be normally in the
closed position.
Fluid is supplied to the FC100 through the 1/8”npt port located on the stainless
steel fluid section of the valve.
Summary of Contents for B12-1686