background image

PRO9776Z

Security and Remote Start

Quick Installation Guide

For Complete Installation Guide and Technical Support 

Please Visit

www.voxxuniversity.com

Or Call

1-800-225-6074

Notifications

Feature Programming

Remote Programming

1 Chirp

2 Chirp

3 Chirp

4 Chirp

5 Chirp

6 Chirp

1 Lock / Unlock Func

on

500ms

3.5sec

500ms L, DBL UL

DBL L, 500ms UL

DBL L, DBL UL

500ms L, 350ms UL

2 Igni

on Lock

OFF

ON

3 Igni

on Unlock

OFF

Unlock All

Unlock Driver

4 Exterior Illumina

on

OFF

With Arm

With Disarm

With Arm & Disarm

5 Auto Relock

OFF

Auto Lock Only

Auto Lock & Arm

6 Auto Arming / Locking

OFF

Auto Arm Only

Auto Lock & Arm

7 No

�fi

ca

on Sound

Both

Siren

Horn

8 Horn Timing

16ms

30ms

40ms

50ms

10ms

9 Valet Override Method

Valet

Custom Code

Stand Alone Valet

10 Driver Priority Unlock

OFF

ON

11 Silent Choice

OFF

From Transmi

er

OEM Style

12 Security Pro

le

All On

Doors o

Hood / trunk O

All O

All On w/ OEM RS

13 Door Trigger Input

Nega

ti

ve

Posi

ve

14 Park Light / Trunk Swap

OFF

ON

15 Data Port Protocol

ADS

DBI

1 Chirp

2 Chirp

3 Chirp

4 chirp

5 Chirp

6 Chirp

1 Defrost Output

Pulsed

10min

RS Run

me

2 RS Start No

�fi

ca

on

ON

OFF

3 RS Run

me

5min

10min

15min

20min

45min

60min

4 RS Parking Lights

Steady

Flashing

5 Engine Con

rma

on

Tach

Voltage

Data

Hybrid

6 Voltage Level

>0.5v B4 Start

<0.5v B4 Start

7 Igni

on 2 Output

Igni

ti

on

Accessory

Start

8 Igni

on 3 Output

Igni

ti

on

Accessory

Start

9 Accessory Output

Accessory

Igni

on

Start

10 Transmission

Auto

Manual

11 Max Crank Time

0.8sec

1.0sec

1.5sec

2.0sec

3.0sec

4.0sec

12 Diesel Delay

OFF

Diesel 10

Diesel 15

Diesel 20

Diesel 30

13 Temperature Start

OFF

ON

14 Crank Dura

on

Averaging

Preset

15 RS Shock Override

Shunt un

ti

l Clear

Shunt RS Cycle

Shunt From TX

16 Turbo Timer

OFF

3min

5min

10min

17 Start Ac

va

on

Two Press

One Press

Three Press

18 RS Lock Func

on

No Change

UL Before L A

er

UL Before Start

Lock A

er Start

19 Factory Disarm Output

Single Pulse

Double Pulse

350ms

500ms

800ms

Same As Bank 2, F1

20 Addi

onal Unlock Pulse

No Pulse

IGN, ACC, GWR

IGN,ACC,GWR,PASD

Fe

at

ur

es

Feature Bank 2

Op

ons

Fe

at

ur

es

Feature Bank 3

Op

ons

Negative Output Control (NOC)

AUX Output Control

1 Runtime Expired

2 Remote Shutdown

3 Brake On

4 Manual Mode

5 Hood Open

6 Low / No Tach

7 Tach Programming

8 High Tach

1 Shock

2 Trunk / Hood

3 Door

Any AUX output can be configured using the AUX Control Menu. This feature is only 

accessible via FlashLogic Weblink or Weblink Mobile.

Negative output control allows any NOC to be programmed for any one of nineteen (19) 

options. This feature is accessible via FlashLogic Weblink or Weblink Mobile.

Alarm

When the alarm is triggered the system will provide feedback to the user. Upon disarm, 

the system will beep 4x and flash the LED to indicate the Alarm Trigger Zone.

Chirp Delete

System ARM/DISARM chirps can be toggled ON or OFF without entering the Feature 

Bank programming.
1. 

Turn the ignition key ON/OFF.

2. 

Press and release the valet button 3x.

The system will respond with one (1) chirp for ON and two (2) Chirps for OFF. This 

feature will not affect alarm trigger or programming. 

User Programmable LED

System LED notifications can be turned ON or OFF without entering Feature Bank 

programming.
1. 

Turn the ignition key ON/OFF, ON/OFF.

2. 

Press and hold valet button for five (5) seconds.

The LED will flash 1x for ON, 2x for OFF. This feature will not affect LED flash during 

programming.

Remote Start

If the remote start fails to start the vehicle, the system will flash the vehicle parking 

lights to indicate the cause.

The PRO9776Z includes two (2) programmed remotes. If required, additional remotes can 

be programmed to the system. Remote Programming is located in Feature Bank 1. To enter 

Remote Auto Programming:

1. 

Turn the ignition key to ON.

2. 

Press and release the valet button 3x. System will beep and flash the parking lights 1x.

Press the lock button on each remote. The system will beep 1x to indicate the remote has 

been programmed. If programming one (1) button remotes, press the Start button. Only 

primary remote functions are auto programmed. This Includes Lock, Unlock, and Trunk/

Start.

If using AUX output control, the remote channel must be manually programmed to 

the system AUX output. Please see the complete installation guide for manual remote 

programming instruction.

Note: If programming 2-Way remotes, wait for remote to beep before programming 

another remote. This beep is confirmation that a 2-Way response has been received from 

the main module.

The PRO9776Z Feature Banks can be programmed by using the valet button and remote. To 

enter Feature Bank programming:

1. 

Turn the ignition key to ON.

2. 

Press and release the valet button 3x. System will beep and flash lights 1x for Feature 

Bank 1, Remote Programming.

3. 

Cycle ignition key OFF/ON. System will beep and flash lights 2x for Feature Bank 2.

4. 

Press valet button to cycle features. LED will flash to display feature number.

5. 

Press lock button to cycle options. System will beep to indicate option number.

6. 

Cycle ignition key OFF/ON. System will beep and flash lights 3x for Feature Bank 3.

7. 

Press valet button to cycle features. LED will flash to display feature number.

8. 

Press lock to cycle options. System will beep to indicate option Number.

To exit Programming cycle ignition key OFF and wait ten (10) seconds. The System will also 

automatically exit programming after sixty (60) seconds of no activity.

The Feature Banks below can also be programmed using the FlashLogic Weblink or Weblink Mobile.

Please visit www.FlashLogic.com for more detail.

Ch. 5 AUX
Ch. 6 AUX
Ch. 7 AUX

Pulse During Crank

Accessory
Factory Arm
Factory Disarm

Ch. 4 AUX

Lock
Unlock
2nd Unlock
Trunk
Remote Start Status
Igni

on

Pulse A

er Shutdown

Domelight
Headlight
Defrost
LED

10 Second Pulse
15 Second Pulse
20 Second Pulse

30 Second Pulse
Push & Hold
Latch ON/OFF
Latch 10min w/ RS
Latch Run

me

5 Second Pulse

1 Second Pulse

2019 Voxx Electronics. All Rights Reserved.

REV. A

Tach Programming

The installer must manually configure the Engine Confirmation method in Feature Bank 

3, Feature 5. The default method is “Tach”. This method requires using the Green/Orange 

tach input wire. When using the default “Tach” method, the vehicle tach rate must be 

programmed. To enter tach rate programming:
1. 

Turn the ignition key ON.

2. 

Press and release the valet button 3x.

3. 

Turn the ignition key OFF.

4. 

Press and hold valet button.

5. 

While holding valet button, start the engine using the key.

6. 

Hold the valet button for approximately ten (10) seconds. If connected to the vehicle 

Tach source, the system will flash the parking lights 1x every second.

7. 

Release the valet button. The system will turn on the parking lights for two (2) 

seconds to indicate the tach rate is programmed.

The tach rate can also be programmed without the use of a valet button. This is helpful 

when using the OEM remote of CarLink system to control this module. To program the tach 

rate without a valet button:
1. Turn the ignition key to the ON position and start the vehicle’s engine.

2. Wait for Engine RPM to lower to a normal idle.

3. Press and hold the vehicle’s brake pedal.

4. Press the LOCK button on the OEM remote or the Carlink App.
The vehicle’s parking lights will flash 7x to indicate the tach signal has been learned. If the 

parking lights do not flash, locate another tach source and repeat steps 1 - 4 above.

Note:

 Programming tach signal via OEM or Telematics control is only available on Firmware 

v1.47 or Higher.

Data Protocol Selection 

The default data port protocol of this model is ADS (iDatalink 2-Way). This model is capable 

of detecting the correct data port protocol (ADS or DBI) and automatically configuring 

Feature Bank 2; Feature 18. To initialize the detection procedure:

1. 

Press and hold the valet button.

2. 

Cycle the vehicle’s Ignition ON/OFF 2x.

3. 

Release the valet button. 

The system will automatically detect and set the correct data port protocol, ADS or DBI.

Note: 

This feature is only available on module firmware v2.00 or higher.

Shock Sensor

The shock sensor should be mounted to a solid surface in the center of the vehicle. Once 

mounted the shock sensor will require adjustment.

To increase sensitivity: Turn adjustment dial clockwise.

To decrease sensitivity: Turn adjustment dial counter clockwise.

To test sensitivity, strike the vehicle with an open palm. Adjust the dial to provide coverage 

to as much of the vehicle as possible.

Dome Delay Programming

This system can be programmed to ignore the vehicle’s theater dimming dome light. This 

feature will be used when connecting the door trigger input to the dome light circuit for 

alarm trigger. Note: Vehicle windows should be open to prevent accidental locking of keys 

in the vehicle.

Start with all doors closed and the vehicle dome light off.

1. 

Press Lock, Unlock, Lock, Unlock, Lock, Unlock, Lock. LED will light solid.

2.  Open and close the driver door.

The system will monitor the dome light circuit. When the dome light turns off the system 

will set the delay time and add an additional two (2) seconds.

Dome Delay Reset

1. Key ON/OFF, ON/OFF, ON/OFF.

2. Press and hold valet button for five (5) seconds.

The system will beep 1x to indicate reset is complete.

Reviews: