P
RODUCT DESCRIPTION
1
The IMP003 Imperium 5A DC-DC charger converts
direct current into the correct charging voltage for
the onboard battery.
The Imperium 5A DC-DC charger will limit the
charging current to a maximum of 3.1A to avoid
overloading the cabling and it also ensures that no
current can flow from the on-board battery back to
the starter battery, as with all LiFePO4 batteries it is
better not to have a direct connection to any other
type of battery. Because the offered charging
voltage is often too low to fully charge LiFePO4
(14.6V) batteries, the DC-DC 5A charger transforms
this charging voltage to the correct voltage.
When the charger is setup for lead-acid batteries it
operates a 4 step, 3 stage voltage.
When the charger is setup for lead-acid batteries it
operates a 4 step, 3 stage charging profile. When
the charger is setup for lithium batteries it operates
a CC/CV charging strategy
01
Rechargeable battery
Source, starter battery or alternator
S
AFETY IN
S
TRUCTIONS
2
2.1 Saf
e
ty ins
tructions
sta
teme
nt
These safety instructions are divided into 3 categories,
as follows:
Danger, these instructions must be
followed to prevent injury or harm.
W
ARNING!
These instructions must be followed
to prevent damage.
C
AREFUL!
Important advice and guidance.
PA
Y
A
TTENTION!
2.2 Saf
ety regul
a
tions
Read this manual carefully before using the
Imperium DC-DC 5Ah Charger;
Keep this manual near the Imperium DC-DC 5Ah
Charger and ma
k
e it available to the user of the
Imperium DC-DC 5Ah Charger;
As soon as the voltage of the source battery is
available the green Power LED of the charger will
turn on. During the charging process the red Charge
LED will be on. When the battery is fully charged the
Charge LED will turn off.
When the incoming voltage will go under 11.2 V or
12.0 V, the charging process stops to prevent the
source battery being discharged too deep
(depending on the settings).
Only tec
hnically qualified pe
rsonnel should install
the Imperium DC-DC 5Ah Charger;
Use cables with the correct cross-section and
k
eep the cable connections as short as possible.
Use th
e supplied flat plugs a
nd chec
k w
hether
they clamp properly;
Do not place the Imperium DC-DC 5Ah Charger
in a high temperature environment or in direct
sun or with a heat source > 45 ° C;
Avoid damage to the Imperium DC-DC 5Ah
Charger housing;
Do not use a damaged Imperium DC-DC
5Ah Charger.
DESCRIPTION EN OPER
A
TION
3
3
.
1 Ope
ra
tion
Advic
e: fit 5A fuses. T
hese also function as reverse
polarity protection.
When mounting the Imperium DC-DC 5Ah
Charger, choose a place that is dry and
clean;
The Imperium DC-DC 5Ah Charger can be
mounted in any position;
Use at least 1,5 mm² cables for connection and
to ma
k
e the cables as short as possible to
prevent loss of current.
Connection diagram: