Purlette PL400G Owner'S Manual Download Page 5

Intr
oduction

Installation

Maintenance

Troubleshoot

W

arr

anty

Saf
ety

3

Network Connection

 To wake the Purlette system, press and hold the NETWORK button for 3 seconds. The 

network indicator light will remain solid (non-flashing) upon successful connection. If a network connection has not 
been established, the network indicator light will continue to flash and the Purlette system will attempt to establish a 
connection for 10 minutes and then turn off.

Energy Saving Mode

 The Purlette system will automatically enter the energy saving mode if drinking water faucet 

is not used for 3 hours. All indicator lights will turn off in energy saving mode. When drinking water faucet is used, 
an operation panel button is pushed, or the system enters auto-cleaning mode, the Purlette system will exit energy 
saving mode and indicators will illuminate automatically.

Power-on 

All indicator lights flash 3 times once the Purlette system is 

plugged in.

Operation Mode 

Filter indicator lights will remain solid white (non-

flashing) while filters are functioning properly. When the service life of 
a filter expires, the filter element indicator light for the specific filter will 
begin flashing. The other filter light will continue to be non-flashing until 
that particular filter requires replacement.

Auto-Cleaning 

During auto-cleaning, the two filter element indicator 

lights are turned on in alternating sequences. The sequence will be as 
follows: filter element RO ... filter element HYBRID ... filter element RO ...

Operation Panel

RO Filter 

Indicator Light

HYBRID Filter

Indicator Light

Filter Reset 

Push Button

Network

Indicator Light

Network

Push Button

RO

HYBRID

RESET

NETWORK

Summary of Contents for PL400G

Page 1: ...Owner s Manual Reverse Osmosis Water Filtration System Model PL400G Scan QR code for installation video or visit www purlette com...

Page 2: ...t clean and drinkable simpler than ever before Using the accompanying mobile app you can monitor the potability of your water and know at all times exactly how much life your filter has left in it You...

Page 3: ...8 9 10 11 12 13 14 16 19 21 Three Way Valve Drinking Faucet Drain Saddle Water Lines System Diagram Flushing the Filter Network Connection Replacing the Filter Warnings and Precautions Self Troublesho...

Page 4: ...upon water usage and source water quality The Purlette system will enter the auto cleaning mode periodically This is usage based and will occur randomly The Purlette system will make an audible sound...

Page 5: ...stem enters auto cleaning mode the Purlette system will exit energy saving mode and indicators will illuminate automatically Power on All indicator lights flash 3 times once the Purlette system is plu...

Page 6: ...ght DO NOT USE with micro biologically unsafe water or water from unknown sources or quality APPLICABLE WATER municipal tap water APPLICABLE WATER PRESSURE 14 100 psi FEED WATER TEMPERATURE 40 100 F G...

Page 7: ...oot Warranty Safety 5 What s in the Box Purifier Three Way Feed Water Adaptor Valve Drain Saddle 1 4 PE Tubes Locking Clips Quick Connectors Silicon Protective Cover Dust Lid RO Filter Hybrid Filter D...

Page 8: ...ed water adaptor valve Once you have ensured that the cold water supply is shut off disconnect the cold water riser hose fitting from the cold water valve that you just turned off Using an adjustable...

Page 9: ...pressing the one end of the tube into the quick connect fitting Be sure to push it in all the way until you feel it stop otherwise leaks may occur Then slide the locking clip into place to secure the...

Page 10: ...by the provided rubber gasket The stem from the faucet should be accessible from under the sink Place 3 4 washer onto the threaded stem and secure under the counter Place 3 4 nut on threaded stem and...

Page 11: ...side of the drain pipe then put the self adhesive black foam seal around the newly drilled hole Next align and install the 1 4 drain saddle with the drilled hole Attach the drain saddle to the drain p...

Page 12: ...arefully before inserting If you make a mistake push the quick connector in gently with one finger and pull out the PE tube with your other hand The tube should release Do not use force Press the tube...

Page 13: ...If any leaks are detected turn off cold water supply immediately remove locking clips and ensure all fittings are properly installed and tightened Then re insert the locking clips Turn water supply o...

Page 14: ...improve taste HYBRID Filter Manufacturer recommended flush time is 15 minutes RO Filter Manufacturer recommended flush time is 24 hours 15Min Flush for 15 Minutes Step 7 Plug in the Purlette system No...

Page 15: ...er attempting to connect for 10 minutes or when a network connection has been established Disconnect Press the network button for 8 seconds the buzzer will sound a constant D noise Release the button...

Page 16: ...e power cord Remove the dust lid Lift quick release arm Locate the filter handle and gently pull up the expired filter To install a new filter first make sure the filter ports are aligned Press the qu...

Page 17: ...er timer The RO light will start flashing indicating that the RO filter has been selected Short press the RESET button to switch between the RO filter and the HYBRID filter Long press the RESET button...

Page 18: ...eit Avoid strong magnetic devices which may cause fire product damage or circuit failure Avoid wet and dusty areas which can cause circuit damage Do not place heavy objects on the Purlette system Do n...

Page 19: ...s normal for the product to have slight vibration and noise when water is being processed filtered The Purlette system is only intended for indoor installation and use If you do not use the Purlette s...

Page 20: ...can be determined by turning the equipment off and on the user is encouraged to try to correct the interference by one or more of the following measures Reorient or relocate the receiving antenna Incr...

Page 21: ...a decrease in water flow Filter blockage or failure The filter life has expired Filter not in use for an extended period of time over 3 days Filter filters expired or defective Check to make sure thre...

Page 22: ...e lines and pipes for external leaks and tilt the Purlette system to check for internal leaking If leakage is internal water would drain out from the base Please cut off power and water to the system...

Page 23: ...spect to this matter shall be final THE EXTENT OF THE COMPANY S LIABILITY UNDER THIS WARRANTY IS LIMITED TO THE REPAIR OR REPLACEMENT PROVIDED ABOVE AND IN NO EVENT SHALL THE COMPANY S LIABILITY EXCEE...

Page 24: ...PURLETTE VISINI USA INC West Covina CA 91791 1 800 928 7624 support purlette com...

Reviews: