Puricom Europe DENVER Series Installation And Service Manual Download Page 3

 

 

This  message  indicates  that  the  system  is 
placing  itself  in  service  position.  If  after  ten 
minutes this message stills in the display please 
contact Technical Service. 
 

2.  Press  MENU  key  for  five  seconds  to  enter 

into  the  internal  programming.  By  pressing 
UP 

and 

DOWN 

keys 

the 

different 

parameters  can  be  selected,  and  pressing 
REGEN  key  we  can  access  to  modify  it 
(selected  parameter  flashes).  With  UP  and 
DOWN  key  we  can  modify  the  selected 
parameter  and  pressing  REGEN  key  a  final 
time  the  parameter  will  be  confirmed. 
Parameters  into  the  internal  programming 
are showed below: 

 

Hour of day: 

 

Languaje: Spanish or English. 

 

Units: Metric system or US units. 

 

Type of regeneration: 

o

  Time  initiated:  Delayed  regenerations 

according  to  selected  frequence  (Ex: 
Softener  will  regenerate  every  three 
days at 02:00AM). 

o

  Meter  immediate:  Regenerations  are 

started  after  treating  the  programmed 
volume of water. 

o

  Delayed  regenerations:  Regenerations 

are 

started 

after 

treating 

the 

programmed  volume  of  water  at  the 
programmed hour. 

o

  Mixed  regeneration:  Similar  to  delayed 

regeneration,  but  it  allows  to  program  a 
maximum 

period 

of 

time 

without 

regenerations. After this time the system 
will start a delayed regeneration. 

Note: 

For 

household 

applications 

mixed 

regenerations are recommended.  

3.  System  capacity:  It’s  necessary  to  program 

the  volume  of  water  that  can  be  treated  for 
the system. To calculate it please follow the 
indications showed as folloes.   

HF

Hardness

HFxm

capacity

Exchange

m

Volume

º

3

º

)

3

(

  

Exchange  capacity:  It’s  the  amount  of 
hardness  that  can  be  retained  by  the  system. 
This  capacity  varies  depending  of  the  softener 
model.  Different  capacities  are  showed  in  the 
table below.  

Hardness:  Total  hardness  of  inlet  water 
expressed in French degrees  ºHF.  

Volume:  Amount  of  water  that  coul  be  treated 
for  the  system.  THIS  IS  THE  PARAMETER 
THAT SHOULD BE PROGRAMMED INTO THE 
SYSTEM.         

Example: 
A Denver softener with 15 litters Denver and an 
inlet water hardness of 35ºHF.  

3

6

,

2

35

90

)

3

(

m

m

Volume

  

2.6  must  be  programmed  inside  capacity 
parameter.  

HISTORIC MENU:  

By pressing UP and DOWN keys simultaneously 
we access to historical data about the operation 
of the softener.   

  

Regenerations:  

To  start  an  immediate  regeneration  it’s 
necessary to press REGEN key for five seconds.  

To  cancel  the  current  stage  of  the  regeneration 
it’s  only  necessary  to  press  any  key.  It’s 
important  to  remember  that  the  stage  could  be 
only  cancelled  when  the  motor  of  the  valve  is 

Resin 

Capacity 

6 Litters 

36ºHFxm

12.5  Litters 

75ºHFxm

15 Litters 

90ºHFxm

30  Litters 

180ºHFxm

Reviews: