4
1
)
OIL WARNING SYSTEM
When the oil level falls below the lower level, the engine stops automatically.
Unless you refill with oil, the engine will not start again.
2
)
ENGINE SWITCH
The engine switch controls the ignition system.
①
ON (run)
Ignition circuit is switched on. The engine can be started.
②
OFF (stop)
Ignition circuit is switched off. The engine will not run.
3
)
ECONOMY CONTROL SWITCH
When the economy control switch is turned “ON”, the economy control unit
control the engine speed according to the connected load. The results are
better fuel connection and less noise.
4
)
DC CIRCUIT PROTECTOR
The DC circuit protector turns off automatically when the load exceeds the
generator rated output.
CAUTION:
──────────────────────
Reduce the load to within specified generator rated output if the DC circuit
protector turn off.
───────────────────────────
5
)
FUEL TANK CAP AIR VENTKNOB
The fuel tank cap is provided with an air vent knob to stop fuel flow. The air
vent knob must be turned once clockwise from the closed position. This will
allow fuel to flow to the carburetor and the engine to run.
When the engine is not in use, tighten the air vent knob counterclockwise until it
is finger-tight to stop fuel flow.
6
)
FUEL COCK
The fuel cock is used to supply fuel from the tank to the carburetor.
2
1
2
1
C
LO
SE
O
P
E
N
CLOSE
OPEN
ON
OFF
DC PROTECTOR
ON
OFF