1 6 |
P a g e
PURETEC
6.1
Operational
Screens
On systems with the UV monitor, the system will display the same screens as on the PURETEC
5.1
except the UV Intensity replaces the home screen. The UV Intensity screen displays the level of
UV light detected by the sensor. UV intensity can be affected by poor water quality, scaling on
the quartz sleeve and/or sensor, lamp failure or lamp expiring. The following screens show the
UV Intensity dropping.
Below 56%, the numbers and warning sign turn red and an audible chirp is given by the ballast
every 15 seconds. Below 51%, the screen is solid red and a constant audible alarm is given. This
alternates with a screen indicating “water may be unsafe for consumption”. With the solenoid
module, the controller de-activates the solenoid valve, shutting off all water flow.
audible chirp every
15 seconds
audible chirp every
15 seconds
constant audible
alarm
cycles with red low
uv screen
Lamp Countdown Sequence
The system counts down the number of days until a lamp change is required.
PURETEC
6.1
PURETEC
5.1
PURETEC
4.1
At thirty days remaining, the LED or display screen will change to a yellow caution indicator.
At seven days remaining, the sytem will additionaly repeat an audible chirp. Past the zero day
threshold, the LED or display screen changes to solid red with a continuous buzzer.
PURETEC
6.1
PURETEC
5.1