Puretec QT18 User Manual Download Page 6

6

 

Installation & Operation Manual

Copyright © Puretec Ltd 2015

Faucet

Escutcheon

O-ring

display

battery seat

circuit board

battery
(CR2032)

Base upholder

Counter Top

Lock washer

1/4"

Compression

Nut

1/4" Tube

Cone Washer/olive

Locking Nut

Plastic Washer

Gasket

Faucet Connections

Figure 3

Battery Installation - 

LED reminder light

1.  Remove the black battery seat from the 

faucet lever handle (see figure 3).

2.  Install battery into the battery seat, 

positive side up.

Note: red light flashes 

twice and then followed 
by the blue light

3.  Reinstall battery 

seat assembly 

into the faucet 
lever

Important note: Battery must be replaced when 

changing cartridges.

5.  Red light flashes indicates your cartridges 

are due to be changed (usage has 

exceeded 3,000 minutes or 12 months). 

Please change the battery when 

changing the cartridges

.

Positive 
side up

Negative on 
the PCB

4.  Blue light flashes during normal operation.

Faucet

Escutcheon

O-ring

display

battery seat

circuit board

battery
(CR2032)

Base upholder

Counter Top

Lock washer

1/4"

Compression

Nut

1/4" Tube

Cone Washer/olive

Locking Nut

Plastic Washer

Gasket

Faucet

Escutcheon

O-ring

display

battery seat

circuit board

battery
(CR2032)

Base upholder

Counter Top

Lock washer

1/4"

Compression

Nut

1/4" Tube

Cone Washer/olive

Locking Nut

Plastic Washer

Gasket

Summary of Contents for QT18

Page 1: ...3497 Licence No WM 74726 Australian Certification Services User Guide Quick Twist Undersink Water Filter System QT18 For correct operation installation it is essential to observe these instructions M...

Page 2: ...efore or after the system Operation The Puretec QT18 system is designed to run economically for many years and this is dependant on the initial installation and periodical maintenance Flush systems fo...

Page 3: ...water line and connect the Smart Tee Reinstall the previous connection to the tee valve 3 Connect the pressure limiting multivalve to the Smart Tee with a length of white tubing 4 Choose the best posi...

Page 4: ...if any before leaving the unit After installing cartridges flush unit for 5 10 minutes Use Guidelines Minimum operating pressure 100 kPa Maximum operating pressure 875 kPa Do not allow exposure to tem...

Page 5: ...collet against body and slide tube out of fitting 2 Fitting grips before it seals Ensure tube is pushed in to tube stop HOW TO USE QUICK CONNECT FITTINGS 3 Tube is secured in position Figure 2 Figure...

Page 6: ...eat assembly into the faucet lever Important note Battery must be replaced when changing cartridges 5 Red light flashes indicates your cartridges are due to be changed usage has exceeded 3 000 minutes...

Page 7: ...elines 1996 ND Not Detected This appliance meets the domestic water treatment appliance Standards AS NZS3497 for the following water treatment processes Class Treatment type Function Pass I Microbiolo...

Page 8: ...no circumstance be held liable for damages consequential or otherwise or delays caused or faulty manufacturing except as excluded by law Applicable to all above is that the Warranties need to be appro...