11
Quick Twist Water Filter System with Tripla LED Mixer Tap
PART 2
Filter Cartridge Installation
This system comes complete with an installation kit enabling it to be connected to 15mm
(½”) male thread.
Installation requirements
1. 15mm (½”) Cold water line - mains only
2. Supply pressure: 100-500 kPa.
3. Supply temperature 3° - 38°C.
4. Suitable location for faucet.
Alternative fittings may be required if being connected to anything other than 15mm
(½”) copper pipe. No electrical or drainage requirements needed.
Installation Procedure
1. Select suitable location that is close to the point of filtered water delivery (eg. sink).
Remember to allow access room for changing filters and a suitable place where water
spillage will not cause damage. Location should not be in direct sunlight.
2. Isolate water supply and cut copper pipe ready to install the tee adaptor and ballvalve.
Filter Cartridge Installation