Components & Selected filters

Water storage tank

Deliver-valve

Water supply connector

Drain saddle

Tank ball shut-off valve

Tubing

¨

Selected filters

¨

Components

Infra-red cartridge filter

PRO

P

URE

DRINKING   WATER   S YS TEM

T.

D.

S

UVC-LIGHTING

ULTRAVIOLET WATER STERILIZER

Mineral cartridge filter

UV water sterilizer

TDS meter

Infra-Red

Mineral

European ceramic faucet

 

 

ROYAL Reverse Osmosis Drinking Water Systems

 

 

ROYAL Reverse Osmosis Drinking Water Systems

A.With everything connected, turn on the water check for leaks. 

B.Make sure the storage tank shut-off valve is "OFF". Open the sink 

top faucet. 

C.Within a few minutes (up to 15) the water will start to run from the 

faucet slowly.

D.Let the water run for at least 30 minutes. This flushes the carbon 

filters on first time use.

E.After initial flushing, open the shut-off valve on the tank and close 

the sink top faucet. 

F.Tank will now full of water (usually 2 to 3 hours) after the tank has 

filled. Open the sink top faucet and drain all water until the storage 

tank is empty and there is only a small flow from the sink top 

faucet.*** DO NOT USE FIRST TANK OF WATER.*** 

G.Close the sink top faucet. The system is now ready for use. 

H.Change filters regularly every 6 to 12 months and have the 

membrane checked annually.

Caution

0

1.Do not use hot water (over 45 C)!

2.Do not freeze the machine!

3.Switch off electricity and water source if away for more than 5 days, 

and drain out pure water.

Operation regulation

Summary of Contents for RS-103TDS

Page 1: ...103TDS 06 LCD display 07 Tubingconnection diagram 08 Installation diagram 09 Change filters 10 Change membrane 11 Operation regulation 13 FAQ 14 Maintenance checkinglist 15 Memo Thank you verymuch for selectingPure Pro Water Corp In order to bring the best use of your system please read the user s manual carefully before installation and follow the regulations Memo RO Computer Controller T D S XI ...

Page 2: ...terproduction This allows for betterassurance that there is adequate wateravailable when desired even during heavyuse times ofthe day PurePro ROYALRO with itssupreme quality ensuresa great waterflow rate with absolutely the leastwasting of water The newly designed ROYAL RO system is user friendly with design simplicity in mind It requires no tools for filter changes Use twist and quick change cart...

Page 3: ...ee Q What factors affect thequantity and the quality ofthe water production There are four major variablesto consider 1 Pressure The greater the water pressure the better water quantity and quality it produced Water pressure of 60 PSIis ideal 0 0 2 Temperature 76 F is the ideal water temperature for R O 40 F water will 0 cause the production of R O water to fall to half of that at 76 F The maximum...

Page 4: ...F Open the sink top faucet C Within a few minutes up to 15 the water will start to run from the faucet slowly D Let the water run for at least 30 minutes This flushes the carbon filters on firsttime use E After initial flushing open the shut off valve on the tank and close the sink topfaucet F Tank will now full of water usually 2 to 3 hours after the tank has filled Open the sink top faucet and d...

Page 5: ...o enhance the quality of your drinking water We are using NSF approved post carbon to guaranteethe taste ofwater 5 Micron Sediment Filter PRO PURE DRINKING WATER SYSTEM Service Life CTO Carbon Filter RS300ST With only five micron rating It is effective in removing dirt rustand sand particles RS300ND It takes out 99 of the chlorine and organic chemicals It provides enhanced reduction of taste odor ...

Page 6: ...housing To the tank To the faucet Input water Flow restrictor Todrain out tube ROYAL Reverse Osmosis Drinking Water Systems ROYAL Reverse Osmosis Drinking Water Systems Micro computer controller PRO PURE DRIN KIN G WATER SYSTEM PRO PURE DRIN KIN G WATE R SYSTE M 6 Remove the membrane by a pincer 7 Install the membraneby carefully pushing the spigotend into the socket at thefar end ofthe housing un...

Page 7: ...oRO system 1 Unplug electricity 6 Drain out 1Gallon of waterto purify replacement filters LCD display RO Computer Controller T D S XI ppm Time X 10m FULL FLUSH WORK SOURCE MANUAL T D S Time MANUAL FLUSH RESET Function express FULL FLUSH WORK SOURCE MANUAL Pump stops producingwhen tank isfull of purewater Flushing RO membranefor 45 seconds The system beginsto produce water The system startsto funct...

Page 8: ...or tubing ToRO system Tankball shut off valve ToRO system Deliver valve Water supply connector Towater source pipe ROYAL Reverse Osmosis Drinking Water Systems ROYAL Reverse Osmosis Drinking Water Systems Tubing connection diagram Faucet Tank Drain Input water CONNECTING THE COLORTUBING A Connect theWHITE tubing tothe water supplyconnector B Connect theBLUE tubing tothe sink topfaucet C Connect th...

Reviews: