13
14
MoRe THInGs YoU sHoUlD KnoW
ozone and Your Health
After you activate your PurePro
®
Tower Professional Air
Purifier, you may notice a new clean scent. Ozone is the
scent you smell. Ozone is a combination of three oxygen
atoms. The PurePro
®
Tower Professional Air Purifier utilizes
an ionizing process which results in very low
ozone emission.
The PurePro
®
Tower Professional Air Purifier complies with
U.S. safety requirements for low ozone emission (less than
50 parts per billion) and meets the UL867 standard for
consumer products. UL867 is the Underwriters Laboratories
Inc. standard for safety for electrostatic air cleaners.
Individuals with a history of respiratory disease, asthma,
heart disease, lung disease, breathing problems or
concerns about ozone should ask their doctor whether
the concentrations of ozone generated by this or other
commercial ionic air purifiers are appropriate for their
specific health needs.
oRDeRInG an eXTRa esP Cell, PRe-
fIlTeR seT anD oXYGen PlUs™ fIlTeR
Enjoy virtually uninterrupted air purification by ordering an
extra ESP cell, pre-filter and Oxygen Plus™ filter set today.
This way you can always have a clean and thoroughly dry
set available to insert into your PurePro
®
Tower Professional
Air Purifier whenever the other filters are being cleaned and
thoroughly dried.
Visit our website at
www.thepurepro.com
or call
1.800.875.8577
to order your new ESP cell, Oxygen Plus™
filter and pre-filter today.
TRoUble-sHooTInG
Reason
Machine is un-
plugged.
Unit has not been
turned on.
Control button has
not been pushed.
ESP cell and
pre-filter are not
completely inserted.
Oxygen Plus™ filter
is not completely
inserted.
Too much dust has
accumulated.
ESP cell is wet.
Too much dust has
accumulated or in-
ternal parts are wet.
Trouble
Unit will not
turn on
Red CLEAN
light is on
Fan off
Excessive
noise
Remedy
Check if plug is loose.
Insert plug into
socket.
Push control button.
Check to see that the
ESP cell and pre-filter
are completely seated
in housing.
Check to see that the
Oxygen Plus™ filter is
completely seated in
housing.
Turn off, unplug
and clean using
instructions from the
“CleanInG &
MaInTenanCe”
section.
Clean and dry
ESP cell and
pre-filter thoroughly.
Keep the machine dry.
*SEE
“CleanInG & MaInTenanCe”
SECTION
Summary of Contents for Professional air purifier
Page 1: ...PP051408 Owner s Manual...