background image

 

PureMate

TM                                                                                                                                                                                          

5      

                                         PM 906 Digital Ultrasonic Humidifier

 

 

OPERATING INSTRUCTIONS 

 

 
Before getting started, please remove the PM 906 from its box and allow it to become accustomed to the room temperature for at least 
30 minutes especially if the machine is cold from the outside air. The PM 906 is designed to operate at temperatures between 5-

40 ºC 

and relative humidity of less than 80%.

 

 

Operation steps:

 

Take the water tank out of the unit, open the water tank cover, and fill the tank with clear water. Close the cover, and put the tank onto 
the base unit carefully. 
 
Put the nozzle into the socket on top of the water tank. 
 
Connect  the  main  supply,  switch  on  the  unit  (NEVER  RUN  THE  UNIT  WHEN  THERE  IS  NO WATER  IN WATER  BASIN),  the  main 
connection lamp will be on. The unit starts working. 
 

 

1. 

Put the machine on a flat surface.

  

2. 

Fill the water into the water tank, and then tighten the tank cover.

  

3. 

Put the water tank on the main body.

  

4. 

Check if the rated voltage meets the input voltage, and plug in the socket.

  

5. 

Switch on the machine; the background light of LCD will be on. The machine begins to work.

 

6. 

Touch the symbol “MAX-MIN”, you may adjust the mist volume. On the remote control, just press the button of “MIST 
VOLUME”

.  

7. 

Touch the symbol “ION”, the Negative ion generator works. On the LCD display, it shows the shape of trees.

    

 

Touch again to stop the function.

  

8. 

Touch the symbol “HEATING”, the warm mist will come out after 10 minutes. On the LCD display, it shows the shape

    

of 

fire. Touch again to stop the function. Mist will become cool.

  

9.  Constant  humidity: 

Before you touch the symbol “HUMIDITY”, LCD display shows the current humidity. You may set the 

humidity arranged from 45%RH to 90%RH. Press once, it will increase by 5%RH . When it reaches 90%RH, press again, it 

will go back to 45%RH. After you set the expected humidity, the machine will keep the memory after 5 seconds . 5 seconds 

later , LCD display shows the current humidity. If the expected humidity is less than the current humidity, the machine will be 

in sleeping state. But if the expected humidity is higher than the current humidity, the humidify function will work. 

10. 

Timer setting: There are 12 timer setting: 1,2,3,4,5,6,7,8,9,10,11,12 hours. Touch the symbol “TIMER”, LCD display shows 

the timer. The timer shows the rest operation time and decrease by 1 hours, i.e., if set the timer at 12 hours, LCD display 

shows 11 after one hour.

 

11. 

Once the water in the basin is too little to keep the machine working, the machine will automatically stop working. LCD shows 

the shape of lack of water. Refill the water, and the machine will restart.

 

 

 

Summary of Contents for PM 906

Page 1: ...PureMateTM 1 PM 906 Digital Ultrasonic Humidifier INSTRUCTION MANUAL PureMateTM PM 906 DIGITAL ULTRASONIC COOL WARM MIST HUMIDIFIER WITH IONISER SUPER TECH HEALTH English 2015 PM906...

Page 2: ...lower water basin when the unit is operating Do not scratch the transducer Do not touch the mist output when producing warm mist Do not submerge this device in water Water or cleaning liquids may only...

Page 3: ...tton for setting the mist release intensity 4 Heating button for switching on off the water heating mode 5 Humidity button for setting the relative humidity in the room 6 Timer setting button 7 Displa...

Page 4: ...Humidifier On Off icon 25 Room humidity preset humidity indication 26 Humidity level intensity indication REMOTE CONTROL The PM 906 is equipped with a very useful remote control You can activate the r...

Page 5: ...utton of MIST VOLUME 7 Touch the symbol ION the Negative ion generator works On the LCD display it shows the shape of trees Touch again to stop the function 8 Touch the symbol HEATING the warm mist wi...

Page 6: ...rface of the transducer and wait for 2 5 minutes 2 Using a small brush cotton swab or toothbrush gently clean the mineral film from the surface of the transducer 3 Rinse the transducer with clean wate...

Page 7: ...refill with clean water Power light is on but the machine doesn t work Too much water in the water basin Remove the water tank Take a small cup and remove some of the water from the machine s water ba...

Page 8: ...onsidered normal WARNING If the above recommended solutions do not work please contact PureMate technical support at the telephone number for your region Do not attempt to disassemble repair and reass...