Purelogic PLCM-E4 Instruction Manual Download Page 7

Edition from 05.06.2015 

13

PLCM-E4. 

Ethernet/USB controller of CNC machine

www.purelogic.ru

8 (800) 555 63 74

05. Software installation 

Time of advance calculation of path of PLMach – similar buffer, 

not from Mach3 side, but in PLCM card. The buffer stabilizes the 

work under short lineouts PLCM<>Mach3 and under slowing down 

calculation of Mach.

Note: From one side the more value of these features, the better (the 

buffer is bigger, the work is more stable) but with increase of buffer 

FeedHold will be delayed by the sum of these parameters, i.e. If 

Mach3 buffer=1 sec and PLMach buffer=0,5 sec, CNC-system reaction 

time when pressing FeedHold =1,5 sec + stepper motor braking time 

according to the defined acceleration profile.

Logging – with active logging, log exchange file PLCM<>Mach3 is saved 

to ‘C:\Mach3\

PLСM.log’. When exploring incorrect device work, this file must be 

sent to Purelogic R&D technical Support with the detailed problem 

description. To receive IP-address automatically we recommend to 

leave this item active, if there is a device which can dynamically assign 

IP-addresses (e.g. it can be a usual home network gateway for internet 

connection )in you local network

Receiving address from DHCP-server – we recommend to make this 

item active, if there is DHCP-server in your local net (device which can 

dynamically set IP-address, it can be a common home network gateway 

for access to the Internet).

Usage of the following IP-address – this option must be used when 

there is no DHCP-server which appoints IP-addresses.

Restore IP button allows to reset IP-address of controller to those 

installed by default.

If the controller is not found by the plug-in, follow the instructions in 

item 6, if it is ok, skip item 6.

6. Automatic setting of network connection.

There is a complete solution for quick and easy configuration network 

setting.

In (C:\Mach3\Purelogic), supplied with the devise you will find set_

ip.exe file.

After starting, this application will set up of your PC network 

connections.

In case when there are several network cards are installed (several 

network connections) the program will offer to specify for what 

connection to change the settings.

FOR CORRECT WORK WITH PLCM CONTROLLER IT IS NOT 

RECOMMENDED TO PUT THE SWITCH IN AUTOMATIC POSITION.

Fig. 10.

 Restore IP – reset IP to pre-defined

Summary of Contents for PLCM-E4

Page 1: ...information 02 Delivery set 03 Technical features 04 Main connectors and indicators 05 Software installation 06 Terms of Warranty INSTRUCTION MANUAL 2 2 3 3 5 16 PLCM E4 Ethernet USB controller of CN...

Page 2: ...packing Number of inputs 12V direct current 6 0 40 169 x 126 x 20 mm 300m 100 kHz 12 buffered LPT port 500 mOhm 0 24 kg 16 optoisolated 5 buffered LPT port Ethernet USB connector type USB B signal tr...

Page 3: ...nstallation to some part of a housing The controller has also converter PWN voltage XP34 for control of frequency converter fig 2 The controller has 3 ports The first port is presented by XS3 connecto...

Page 4: ...t 5 5 output 6 6 output 7 7 output 8 8 output 9 9 output 10 10 input 11 11 input 12 12 input 13 13 input 14 14 output 15 15 input 16 16 output 17 17 output 18 GND 19 GND 20 GND 21 GND 22 GND 23 GND 24...

Page 5: ...ion When choosing PLCM E4 after Next pressing software installation wizard will offer to execute automatic setting of network adapter PC for correct connection to PLCM E4 fig 8 Fig 3 4 Cable type setu...

Page 6: ...nd update internal controller software 4 After successful plug in start PLCM control option will appear in menu MACH3 PlugIn Choose this option If you see the window as it is in fig 8 and you cannot c...

Page 7: ...dynamically assign IP addresses e g it can be a usual home network gateway for internet connection in you local network Receiving address from DHCP server we recommend to make this item active if the...

Page 8: ...rty applies can cause delay of tasks execution in Mach3 which can lead to loosing connection with the controller You can use several network cards when testing and setting the system With help of Doub...

Page 9: ...ct defect 3 2 If the defect is proved warranty repair is carried out 4 We do not assume any responsibility for glass electric lamps starters and expendable materials as well as 4 1 Damaged product cau...

Page 10: ...echnical documentation and is qualified for exploitation Lot number Technical Control Department 4 7 The product which was resold by the initial buyer to the third party 4 8 The product with defects w...

Page 11: ...onsistent technical improvement You can always download our latest versions at www purelogic ru www purelogic ru Contacts Moscow 7 495 505 63 74 Voronezh 7 473 204 51 56 149 Office 160 Leninsky avenue...

Reviews: