PUREGAS, LLC
P4200W2 Series Air Dryer User’s Guide
Page 78 of 113
P012308 - Rev. E
9.13 Testing High Duty Cycle Alarm
NOTE:
For this test, allow the Display Screen to cycle through the information
screens.
9.13.1
Remove the Front Panel (section 8.10 ).
9.13.2
Allow the Compressor run and then turn off.
9.13.3
Immediately after the
Compressor turns off, pull
the ring handle on the Safety
Relief Valve until the
Compressor turns on again.
A High Duty Cycle Alarm
should appear on the Display
Screen.
9.13.4
Allow the Compressor to
turn off.
9.13.5
Press the
RESET Button
to clear the alarm.
9.13.6
Reinstall the Front Panel (section 8.10 ).
If you are unable to create a High Duty Cycle Alarm as described, see section
13.18 for troubleshooting information.