5
INITIAL CARTRIDGE FLUSH AND SYSTEM LEAK TEST
IMPORTANT! – ENSURE CARTRIDGES ARE INSERTED IN CORRECT ORDER!
Note:
You may want to place something under the unit to catch the
water which is released when you unscrew the last chamber for
Step
D.
1.
Remove shrink wrapping
and insert the first two cartridges
only:
SuperBlock
TM
cartridge into
Chamber #1
and
FluorSorb
TM
cartridge into
Chamber #2,
screw the chambers
closed. Screw the last chamber closed also, it should be empty for
now.
A.
Slowly turn on cold water, check newly installed faucet
and all connections for a watertight seal.
*Note: you may hear a
slight “hissing” sound when the filter is working, this is normal
and is due to the built-in flow-regulator.
B.
With your cold water on, gently turn the
Handle
on the
newly installed faucet to the side to allow water flow.
C.
Check again for any leaks on all tubing and filter
connections to ensure watertight connection.
If there are leaks at
input or output ports: ensure that the red and blue tubing is
pushed as far as it can go into the connecting elbows on the unit.
D
. As the first water begins to flow, you may notice a small amount of grey carbon
dust pass through as the cartridges get flushed. Allow the cold water to run on full for
10
minutes
then turn off faucet & shut off water supply to filter via the
Angle Stop Adapter
Valve
.
Remove Shrink Wrapping
and Insert the last
cartridge (
AntiRad-Plus
TM
) in
Chamber #3
and flush the entire system again for
15 minutes
.
Note: First Water may be cloudy during few seconds of every use for about a week
as the Zeolite in this cartridge adapts and releases harmless mineral dust, this will subside
in about 1 week.
E. To Shut off the filter, turn off the faucet
.
Congratulations! Your System is now ready for use.
THE FILTER SYSTEM IS DESIGNED FOR COOL - COLD WATER USE ONLY.
Do not allow hot water to run through the filter system.
Close
empty
until
Step
D.
#2
#1
#3
Red
Input
Blue
Output
SuperBlock
TM
FluorSorb
TM