SAVE THESE INSTRUCTIONS!
- This product is installed to a 4" electrical box or to an
octagon electrical box using the 2" plaster ring provided.
- Minimum electrical box volume must be 6 cubic inches (98
cubic centimeters).
- This product is intended only to be used with the Linear
Suspension series.
IMPORTANT INFORMATION
1718 W. Fullerton Chicago, IL 60614
Ph: 773.770.1195 ● Fax: 773.935.5613
www.PureEdgeLighting.com ● [email protected]
© 2016 PureEdge Lighting. All Rights Reserved.
Doc # 904-CCS-2SQ_2RD_03
Installation Instructions for
2" Round & Square Cable Grip Power
Canopies with Plaster Plate Mount
A
1
CCS-2_-JBOX-_
Install the 2" Plaster Ring
For New Construction
NOTE:
Junction box must be mounted to allow clearance of
1/2" between the face of the junction box and the drywall
surface.
NOTE:
24VDC power wires must be present inside the junction
box. Refer to the installation instructions provided with the
power supply.
1:
Install the 2" plaster ring to the junction box using two
#8-32 screws.
2:
Use a circular saw to cut out the drywall section where the
plaster ring is located.
3:
Install the drywall. If necessary plaster, and finish the
drywall.
4:
Complete the installation by following steps in "
Prepare
Power Cable and Install Cable Grip"
section.
2-1/4"
CEILING
2" PLASTER
RING
#8-32
SCREW
JUNCTION
BOX
1
1
CUT
DRYWALL
2
B
5:
Cut away the drywall where the junction box is located.
6:
Uninstall the existing plaster ring by removing the #8-32
screws.
7:
Install the 2" Plaster Ring to the junction box using two
#8-32 screws.
8:
Plaster and finish around the junction box opening.
9:
Finish Cable Grip installation by following steps in
"Prepare
Power Cable and Install Cable Grip"
section.
CEILING
For Remodeling
C
CUT
DRYWALL
STANDARD
PLASTER RING
#8-32
SCREW
#8-32
SCREW
6
6
5