Note:
1)The default humidity is 50%RH, to increase and decrease as follow:
20%-25%-30%-35%-40%45%-50%-55%-60%-65%-70%-75%-80%-85%-90%
2)Environmental humidity and machine set humidity will decide the status of
the
compressor and fans follow:
Environmental humidity ≥ machine set h3%, compressor and fan start
running. Environmental humidity
<
machine set h3%, compressor and fan
stop running.
During continuous mode, humidity setting is unavailable. Continuous mode light turns
on and the screen will display the current humidity. Press this button to switch to
normal mode where the humidity setting will be available.
Press this button, the water pump will start the forced drainage system with the light
on. After the system works for 30 seconds, the water pump will stop work with the light
off.
11
EN
STARTING THE DEVICE
1
.
Plug in the machine and you will hear a "beep"
sound
.
2
.
Press the "Power" button once and the LCD will open. When all the
indications
are
normal, the room humidity will appear on the screen.
3
.
Moisture settings. Press the "+" and "-" buttons to select the desired humidity
of the
space. When the moisture selection is at least 3% more than room
humidity, the
dehumidifier starts its operation. When the moisture selection is
at least 3% less
than room humidity, the dehumidifier stops operating.
4. When the relative humidity levels we select are less than 30% RH
the
dehumidifier starts continuous dehumidification.
5. Setting a preset time: Press the "Time" button and the "hour" button
on
the
control panel will light up, press "+" and "-" to set the operating time.
6. Disable: Press the "Power" button as the machine runs, the dehumidifier
will
shut
down and all the lights will go off.
DRAINAGE INSTALLATION
Install the included drain pipe to the draining nozzle on the machine and direct
the
pipe to the desired area before operate the machine.
The pump has the ability to remove sewage at a height of up to 5m and with a
horizontal length of up to 30m.