8
[
EN
]
1
2
.
TROUBLESHOOTING
problem
Cause
Solution
The unit does not work
There is no voltage in the unit
Plug the plug into the wall socket
The on switch is off
Turn the switch to the on position
The water tank is full
Empty the water tank
container
Δεν είναι δυνατή η αφύγρανση
Ambient temperature is lower than
+ 5 ° C
Under these conditions the
dehumidifier becomes ineffective.
It is recommended to deactivate
the dehumidifier
Ambient temperature exceeds 35 ° C
The compressor is overloaded and
switches off automatically. It is
recommended to deactivate the
dehumidifier.
Ambient air humidity is lower than
50%
Under these conditions the
dehumidifier becomes ineffective.
It is recommended to deactivate the
dehumidifier
The air filter is very dirty
Clear the air filter
It is not enough time to dry out
Leave more time to dry
The compressor does not start
Thermal protection is defective
Contact Puredry Hellas
The capacitor is defective
Contact Puredry Hellas
The fan is off
The dehumidifier performs a defrost
cycle
The dehumidifier will automatically
turn on the fan after a few minutes.
If not, the damage must be repaired
by Puredry Hellas.
The fan does not work
Contact Puredry Hellas
The unit is constantly
defrosted and there is an ice
block in the heat sink
Defect control system
Contact Puredry Hellas
The room temperature is below
+ 5ºC
The unit is designed to work
above + 5 ° C.
Faulty bypass relay valve
Contact Puredry Hellas
The unit does not thaw
Faulty temperature sensorς
Contact Puredry Hellas
Defect control system
Contact Puredry Hellas
Faulty bypass relay valve
Contact Puredry Hellas
Ο χρονοδιακόπτης
δεν λειτουργεί
It is not enabled
Contact Puredry Hellas
Water tank is ful
The water collection tank must be
emptied and re-installed.
Defective time gauge
Contact Puredry Hellas
1
3
.
MAINTENANCE
Always turn off the device and disconnect the cable before performing maintenance procedures. All service
procedures below are to be performed with the unit in the socket. Perform before each use or as required.
CHECK THE ELECTRICAL SYSTEM
Check the electrical cable for damage at regular intervals
.
PROTECTION FROM DUST
Keep dust away from surfaces and areas when dry
Summary of Contents for DESIGN SERIES PD 130LA
Page 1: ...DESIGN PD 130LA...
Page 2: ......
Page 3: ......
Page 4: ...4 GR...
Page 5: ......
Page 6: ......
Page 8: ......
Page 9: ...9 GR 1 2 14...
Page 10: ...15 ELECTRICAL DIAGRAME DEHUMIDIFIER ELECTRIC WIRING PUMP CONNECTION WIRING OPTION 10 EN...
Page 11: ......
Page 12: ...INDUSTRIAL DEHUMIDIFIER DESIGN SERIES PD 130LA...
Page 21: ...15 ELECTRICAL DIAGRAME DEHUMIDIFIER ELECTRIC WIRING PUMP CONNECTION WIRING OPTION 10 EN...
Page 22: ......