background image

 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 

 

 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 

Whisper 60 modular  
12/24 Volt DC  230VAC 

User Guide and Installation handbook 

PureWater – H. Fehlemann  

Entsalzungsanlagen 

Bodelschwinghstrasse 37   

33142 Büren 

Germany 

 

www.watermaker.de  

[email protected] 

 

 

 

Whisper 60 modular 

 

 

 

 

Summary of Contents for Whisper 60

Page 1: ...modular 12 24 Volt DC 230VAC User Guide and Installation handbook PureWater H Fehlemann Entsalzungsanlagen Bodelschwinghstrasse 37 33142 B ren Germany www watermaker de purewater watermaker de Whisper...

Page 2: ...nnections to PH Stabilizer Only COMPACT Models 9 4 4 01 Controls at the front Panel 9 4 4 1 Electric Control Box Option 10 5 0 How to use the System 11 Preservation Configuration Flow Diagram 12 6 0 M...

Page 3: ...de The Whisper 60 modular individual parts Basic Unit Filtersystem Whisper Feed Pump Vane Pump 230V Main Panel Pressure Vessel ETD The dimensions of Motor and pump are subject to change because differ...

Page 4: ...oder in Gebieten wo Kraftstoff und l im Seewasser ist Don t use the unit in ports and areas where the seawater is contaminated with fuel and oil 5 Wenn Sie die Anlage in Frisch oder Brackwasser betre...

Page 5: ...ncentrated solution is increased to above the osmotic pressure fluid flow will be reversed This condition called Reverse Osmosis can be established by artificially pressurizing the more concentrated s...

Page 6: ...0 Whisper 60 System 2 1 The general scope of application for the WHISPER systems You can use the WHISPER systems without restriction in all oceans around the world and in brackish water areas Take ca...

Page 7: ...The Pre Filter is a 5 changeable filter cartridge and protects the Membrane from fine particles Sample Valve at the panel not used on COMPACT Systems With the Sample Valve you are able to take a water...

Page 8: ...The diversion Valve is located at the right side of the Main control panel There is an emergency gray button to override the valve Only to be used when the controller is not working Push and turn to...

Page 9: ...Bar Low Pressure 7 12 Bar Maximum Salinity 46000 ppm ppm Parts per million Temperature Range 1 C to 45 C PH Range 2 11 The produced fresh water is better than WHO requirement 4 0 Installation 4 1 Req...

Page 10: ...ect either Sea Water operation or Fresh Water Operation The lower connection is for Sea Water the upper connection is for the line from the Carbon Filter FWF System or if installed from the Selector V...

Page 11: ...ft 8mm Line is to drain over board The upper connection of the Valve at the Strainer has to be connected with the outlet of the Carbon Filter FWF System The inlet of the Carbon Filter must be connecte...

Page 12: ...s to be connected with the PH Stabilizer Note The PH Stabilizer is not working as a filter but as an injector Therefore the flow is vice versa OUT is where the line from the Manifold Position Fresh Wa...

Page 13: ...of the motor will result in wrong direction turning and the pump rotation is wrong Then connect the Feed Pump Cable to its respective side COMPACT Models have this connected Step 6 Connect a control...

Page 14: ...ee of air you can watch the pressure indicators The low pressure at the panel should read between 8 to 10 Bar and the high pressure Gauge at the ETD should read in normal seawater 40 55 bars If you te...

Page 15: ...Whisper 60 modular Guide Flow Diagram Preservation Configuration 12...

Page 16: ...ugh they do not attack the membranes or other system components directly high concentrations of biological matter can block enough of the product water channels to cause a reduction of as much as 40 o...

Page 17: ...e Selector Valve 1 to the right At the respective connection should be a hose to the cleaning storage tank If you don t have the Selector Valve 1 installed you need to draw a hose from the inlet of th...

Page 18: ...the Membranes Seal in the same position as the old Membrane Most probably you have to change the seal at the new membrane to the opposite position All connections should be greased with silicon grease...

Page 19: ...Whisper 60 modular Guide Flow Diagram with Air Oil Separator 16...

Page 20: ...Whisper 60 modular Guide Flow Diagram Standard Configuration 17...

Page 21: ...8 1 2 12 24V Motor The 12 24V Motor has a Box on top of the Motor You have to determine the Positive connection There is an embossment of and at the bottom You only can see this if you use a light Re...

Page 22: ...Whisper Handbook 9 1The John Guest System 19...