background image

PureLink by Dtrovision 

G

                                                                                                                                                                                                                 

21 

4.5   Command Ack (Acknowledge) Value Response 

When command codes are entered into a terminal emulation program (such as HyperTerminal) and are 

accepted by the system, they respond back to the terminal screen one at a time, as noted below in the 

table. The complete command has executed successfully when all of the entered characters including “s” 

which stands for status, appear. If a command character is not accepted, a different character than the one 

entered appears and all or part of the command has not been executed.   

 

Ack (Acknowledge) Value Response Table 

The following table shows ack value response characters along with their descriptions and meanings, 

which may appear instead of the initially entered character or number. If these characters appear, all or part 

of the command has not been executed. 

 

Table 3.2 Descriptions of Acknowledge (ACK) Signals 

Ack value 

Description 

Input 1 is not connected 

No information in each channel. 

Command Code Error 

Indicates that system has rejected all or part of the command 

Router ID Error 

Indicates that the wrong ID number was entered 

 

Command Code Ack Value Examples 

Command Code 

Entered 

Ack Value as appears in the control 

program 

Explanation of Result 

*255CI01O01! 

 

*255sC I01O01 ! 

The command was successfully executed 

*255CO01! 

 

Command Code Error 

The command was not executed because 

the input number was not included 

*255CI01O01 

 

Command Code Error 

The command was not execu

ted because “!” 

(End) was not included 

*300CI01O01! 

 

Router ID Error 

The command was not executed because 

the actual Router ID and entered Router ID 

did not match 

 

4.6   Connecting Switches 

A switch is an active connection between an input (source) signal and one or more output (display) 

devices. The signals connected in a switch command are either individual signals or groups of signals 

coming through the connectors on the rear of the unit.   

 

The “C” key initiates a Connect command for routing a switch. The characters and numbers that follow the “C” 

command tell the system, which inputs and outputs to connect. The last character “!” is found at the end of a 

command code which tells the system to execute the command. 

 

Summary of Contents for HX-4200-U

Page 1: ...ureLinkTM 535 East Crescent Avenue Ramsey NJ 07446 USA Tel 1 201 488 3232 Fax 1 201 621 6118 E mail sales purelinkav com www purelinkav com For order support please contact your local dealer For techn...

Page 2: ...ain Menu User Guide 9 Chapter 4 Communication Code Configuration 4 1 Control Programmer s Guide 13 4 2 Overview 13 4 3 Command Code Formats 13 4 4 General Rules for Command Codes 14 4 5 Command Ack Va...

Page 3: ...with a 3 wire grounding type plug a plug having a third grounding pin This pin will only fit in to a grounding type power outlet If you are unable to insert the plug in to the outlet contact your elec...

Page 4: ...y and or CPU Boards and Power Supplies used Council Directive 93 68 EEC with Matrix Dtrovision LLC 535 E Crescent Ave Ramsey NJ 07446 201 488 3232 declares under sole responsibility that the product i...

Page 5: ...mpromising design and manufacturing standards the HX 8800 delivers unparalleled quality and value Matrix Switching for up to 8 HDMI Inputs to any 8 HDMI Outputs PureLink s HX Series routers are availa...

Page 6: ...NCTION Navigate menu and control options CREATE Program input channels PREVIEW View saved channel ENTER Save select desired setting CANCEL Revert to previous setting IN1 8 Select input channels 1 8 OU...

Page 7: ...ch ON OFF DISPLAY View menu and system mode FUNCTION Navigate menu and control options CREATE Program input channels PREVIEW View saved channel ENTER Save select desired setting CANCEL Revert to previ...

Page 8: ...placed as shown in Figure 1 1 Front Panel Figure 1 1 POWER Main power switch ON OFF DISPLAY View menu and system mode FUNCTION Navigate menu and control options CREATE Program input channels PREVIEW...

Page 9: ...ow placed as shown in Figure 1 1 Front Panel Figure 1 1 POWER Main power switch ON OFF DISPLAY View menu and system mode FUNCTION Navigate menu and control options CREATE Program input channels PREVIE...

Page 10: ...PureLink by Dtrovision G 10 INPUTS HDMI v1 4 Input ports 1 4 Female type OUTPUTS HDMI v1 4 Output ports 1 2 Female type...

Page 11: ...on settings are recommended for optimal performance x Operational temperature should be 30 C or below x Operational humidity should be 60 or below x Operational environment should be dust free and wel...

Page 12: ...upports HDMI or DVI displays Supporting Function x Supports high resolution up to UHD 4K2K PC Resolution up to 1920 x 1200 60Hz HDTV Resolution up to Ultra HD 4K 4096 x 2160 24 25 30Hz RGB YCbCr 4 4 4...

Page 13: ...ution x Press the CANCEL KEY to return to the initial screen Create Menu x Select an INPUT channel x Press the IN OUT KEY to set a channel x Press the ENTER KEY to save or switch input channels x Pres...

Page 14: ...lay device s EDID information will be displayed z Select Input where selected EDID data will be saved on to Multiple Input can be selected at once z Push enter button to save P will display on the LCD...

Page 15: ...Flow control none and supported settings are Supported Baud Rate 4800 Bps 9600 Bps 14400 Bps 19200 Bps 38400 Bps 57600Bps 76800 Bps 115200 Bps Supported Data bit 5 bit 6 bit 7 bit 8 bit Supported Par...

Page 16: ...using the front panel key of the matrix switcher for HX 4200 1 Go to front of the switcher 2 Press the Menu button 3 Use the Create and Preview buttons to shift up and down 4 Choose 5 Lan and press E...

Page 17: ...Connection Product ID 255 x All Video Audio switching connection becomes clear x Serial communication setting will be restored back to the factory default Baud Rate 19200 Data Bits 8 Parity None Stop...

Page 18: ...mand Code Formats A command code is a series of command characters and numbers used to send commands to the system Commands include basic formulas for creating and disconnecting switches as well as fo...

Page 19: ...end with End byte All s will be executed when Enter is entered The correct Router ID must be entered in a command code Systems will not react to the command if a wrong Router ID is entered The Factor...

Page 20: ...x64 D D Disconnect Disconnect command for both Video and Audio this must precede input and output specification 1 Space Separates the numbers within entries that contain multiple numbers 1 Range Speci...

Page 21: ...e Error Indicates that system has rejected all or part of the command Router ID Error Indicates that the wrong ID number was entered Command Code Ack Value Examples Command Code Entered Ack Value as a...

Page 22: ...and 7 4 7 Disconnecting Switches The characters and numbers in a Disconnect command tell the system which input or output to disconnect The D key initiates a Disconnect command for routing a switch T...

Page 23: ...7 Check Input connection status on Output 7 255 ALLIO Check all Input and Output connection status Router ID Check User can confirm the router s Current ID setting Universal Router ID is 999 Example C...

Page 24: ...t Port Number at 3000 Connection Checking User can check the connection status Example Command Codes Action 255H000 Check connection status Function Key On Off User can enable or disable the function...

Page 25: ...remote locations through the LAN port using WINDOWS XP DOS prompts hyper terminal or TELNET program the control code is fully compliant with RS 232C QWHU 7 1 7 5RXWHU 3 GGUHVV LQ WKH 26 SURPSWG 0HVVDJ...

Page 26: ...Warranty Information 5 1 Firmware Update Instruction How to download new firmware 1 Download Firm Upload application 2 Connect the PC with the HX 4200 through USB 3 Load proper upgrade file and set co...

Page 27: ...PureLink by Dtrovision G 27 5 Press Program to upload file...

Page 28: ...uct or part to replace the defective item 3 Refund to customer the purchase price paid for the defective product All products that are replaced become the property of Dtrovision LLC Replacement produc...

Reviews: