Pure H2O QUATREAU 553-B User Manual Download Page 7

————————————————————

DO NOT TURN THE POWER ON 
TO YOUR SYSTEM UNTIL YOU 
HAVE READ THROUGH THE 
COMMISSIONING STAGES IN THE 
NEXT SECTION. POWERING UP IS 
PART OF THE COMMISSIONING 
SEQUENCES. DAMAGE MAY 
OCCUR IF YOU FAIL TO FOLLOW 
IT CAREFULLY.

————————————————————

Q

UATREAU TOUCH

INSTALLING THE QT553-B
————————————————————
STEP 1

Install the Thermostatic valve in 
accordance with instructions, onto  
the  hot and cold mains. Using the John 
Guest 1/2” - 3/8” reducer included in your 
instillation kit, connect to the temperature 
controlled outlet port (this will maintain 
temperature at or below 42C). 

Using the 3/8” blue pipe enclosed cut a 
length to feed the hot mains water inlet on 
the left side of the QT553-B module.

As part of this installation you will also 
install a separate cold water supply with 
a 1/2” isolation valve. This will control  the 
cold water mains feed to the left and the 
smaller 1/4” cold feed into the front right 
hand side of the QT553-B. 

Connect a John Guest 1/2” -3/8” reducer 
to this cold isolation valve and run a length 
of blue 3/8” PE pipe ready for connection 
to the cold mains water inlet alongside the 
hot water inlet.

To create the secondary cold inlet feed 

connect the 3/8” reducing T into the same 
3/8” pipe at the closest point to isolator 
and run a length of 1/4” pipe to the pure 
inlet on the right hand side of the QT553-B. 
Also connect the 1/4” isolation valve just 
before the inlet. This will be sued for control 
purposes.

STEP 2

With the QT553-B (boiler control module) 
module on the right hand side of the 
cupboard connect the thermostatic hot 
and the mains cold connections using 
the 3/8” blue PE pipe enclosed in your 
installation kit.

Attach the blue 3/8 pipe enclosed to the 
3/8 ports at the back left hand side of the 
unit. Note that hot is furthest to the back 
and cold is attached in front of the hot. 
Both ports are laser etched hot / cold. Turn 
both the hot and cold services until 50% 
open. These connections feed a robust, 
one piece manifold. Whilst a water tight 
seal should be instantly achieved with the 
push fittings, its important to observe and 
listen for any water escaping.

The manifold is very robust and should 
cope with transit but, in the event of the 
system being dropped damage may 
occur. In this event call your supplier and 
request a new 553 manifold.

Now connect the cold water feed to the 
top front right hand side of the 553-B. 
using the 1/4” PE pipe provided. The speed 
fitting will make a water tight seal when the 
pipe is pushed firmly into the port labeled 
PURE INLET. Note that this can be fed by a 
purifier or mains cold water.

If using a purifier to feed the system ensure 
it has been commissioned with a 50psi 

INSTALL ATION

Summary of Contents for QUATREAU 553-B

Page 1: ...BOILING CHILLED SPARKLING HOT COLD Touch INSTALLATION COMMISSIONING AND USER GUIDE...

Page 2: ...NSTALLING THE C20 CS20 C50 CS50 Chiller or Chiller Carbonator range SYSTEM DETAILS PIPEWORK VENTILTION POWER REQUIREMENTS IMPORTANT INFORMATION SECTION TWO COMMISSIONING COMMISSIONING THE QT553 B COMM...

Page 3: ...board asthe mains cold water supply Note that this is in addition to the isolated Mains Cold Water that will be used to feed a cold supply to the system 4 Drainage Trapped upstand located back left ha...

Page 4: ...e of the box to reveal the system so that you don t have to lift it upwards out of the box Carefully place one hand under the front lip of the system next to the filter this will give you a firm hold...

Page 5: ...ourse dictate whether this is possible Before you start cutting ensure that you have set up a jig or a template device to prevent the drill bit moving when you start the cut Once the hole is prepared...

Page 6: ...to tighten the bolts you will pull the tap down onto the work surface and create a tight fit Do not over tighten once the tap is firmly in place stop Your tap is now fixed in place 4 Connect two lengt...

Page 7: ...a length of 1 4 pipe to the pure inlet on the right hand side of the QT553 B Also connect the 1 4 isolation valve just before the inlet This will be sued for control purposes STEP 2 With the QT553 B...

Page 8: ...chiller performs to its specification Failure to install this will void the warranty on this module The Quatreau chiller carbonator is sited next to the 553 B control unit Usually this will be to the...

Page 9: ...250 226 140 391 55 107 47 SYSTEM DETAILS QUATREAU TOUCH Note Requires 40mm diameter hole in counter top positioned minimum 50mm back from the edge of the sink INSTALLATION...

Page 10: ...Mains hot and cold services must have isolators fitted The thermostatic valve should be fixed to the side of the cupboard in which the QT553 B or C20 CS20 C50 CS50 is to be installed Ensure that both...

Page 11: ...ust vented adequately A vent kit should be purchased with each system Ventilation is cut into the base of cupboard under the chiller and a duct run to the kick board The kickboard is also cut to permi...

Page 12: ...E 230V 230V 230V WATTAGE Max consumption 2 56KW 130W 296W Standby consumption 80W 130W 100W START UP TIME 10 minutes 10 minutes MAX WORKING PRESSURE 3Bar 3Bar CO2 CAPACITY 100ltrs carbonated water INS...

Page 13: ...ot elbow inlet on the side of the QT 553B 4 Connect the other braided hose to the cold mains water supply and fit to the cold mains 3 8 inlet elbow on the side of the QT 553B 5 Connect a supply of col...

Page 14: ...anks are full of water you can add the gas bottle to the front of the QT 553B 2 Power up the chiller carbonator you will hear the fan activate and possibly the pump 3 Run the chilled water function at...

Page 15: ...pressure requirements to max 3Bar SECTION H Optimum setting for mains Hot Cold water Finally adjust the flow rate of the mains hot and cold down to a point where it doesn t splash when washing hands T...

Page 16: ...will display boiling and the top left control quadrant cup icon will flash red several times before illuminating red To turn off the boiling water press once any of the four control quadrants QUATREAU...

Page 17: ...p right control quadrant snowflake icon once When the tap is releasing chilled water the top right snowflake will illuminate white and the central screen will display chilled To turn this function off...

Page 18: ...ling The sparkling water function will run for 30 seconds earlier models have an 8 second timeout before automatically switching itself off Note If the sparkling water is spluttering or is not carbona...

Page 19: ...hermostatic valve in a clockwise direction to make the water colder and anti clockwise to make it hotter COLD MAINS COLD WATER To activate touch the bottom left control quadrant sink icon twice To tur...

Page 20: ...chiller carbonator needs to be sited with adequate ventilation to function correctly QUATREAU CS CHILLER CARBONATOR Models C20 20ltr hr chiller CS20 20ltr hr chiller carbonator C50 50ltr hr chiller C...

Page 21: ...ator by a half turn in a clockwise direction To decrease the level of carbonation turn the regulator by a half turn in an anti clockwise direction Between adjustments you must run off several glasses...

Page 22: ...s supported 4 Rotate the canister in a clockwise direction being careful not to cross thread the regulator 5 Rotate until you hear a hissing sound This is the gas being released from the canister It i...

Page 23: ...adjust this function The CO2 canister will need replacing please refer to the sparkling water section in the user guide for details The boiling flow can be controlled by the PRV located on the side o...

Page 24: ...R REQUIREMENTS 1 x 13A socket 2 x 13amp sockets RCD Protected VOLTAGE 230V 230V 230V WATTAGE Max consumption 2 56KW 130W 296W Standby consumption 80W 130W 100W START UP TIME 8 minutes 10 minutes MAX W...

Page 25: ...INSTALLATION DETAIL BY AUTHORISED PURE H2O TECHNICIAN ONLY INSTALLATION DATE INSTALLATION NOTES CONTACT CUSTOMER SERVICE 01483 617000 customerservice pureh2o co uk USER GUIDE...

Page 26: ...Boundary Business Centre Boundary Lane Woking Surrey GU21 5DH United Kingdom www quatreau com QT 06 19 Quatreau is a registered trademark of the Pure H2O Company Limited Copyright 2019 The Pure H2O Co...

Reviews: