background image

Real Time Clock Setting

7

8

     Set the year

     Set the month

.

⑤ 

      Set the date

9

10

Press and release the 

S BUTTON 

to advance

one year until the correct year appears. 
After the year is set, press     

 BUTTON

, the Month

figure will appear

.

 

Press and release the 

S BUTTON

 to advance 

one month until the correct month appears.
After the month is set, press     

 BUTTON

, the Date

figure is flashing automatically

.

  

Press and release the 

S BUTTON

 to advance 

one day until the correct month appears.
After the day is set, press     

 BUTTON 

to exit the

setting mode.

Body Temperature

Illustration For Use

Illustration For Use

Note:

 

Oils or cosmetics on the forehead may give a lower temperature

    reading than the actual one. 

● 

Remove dirt from the forehead before

    taking a measurement. Wait at least 10 minutes after washing the

    forehead area before taking a reading.

Check before each use that the lens is intact. If it is damaged, 

    contact your retailer or the service address.

Bear in mind that the thermometer needs to have been in the room

    in which the measurement is taken for at least 30 minutes before

    use.

U

Before each measurement, make sure that the device is in the 

    appropriate mode for the measurement that you wish to take

.

● 

● 

● 

sers and the thermometer should be in the same ambient 

    temperature.

● 

Before measurement:

To measure forehead temperature:

Figure 1

1. Install the forehead cap.

 

 

2. Press the      

BUTTON  

to switch on the thermometer and the 

    display is activated to show all segments. 

3. 

4. Place the probe with the forehead cap fitted on the temple

.

5. Press the 

START BUTTON 

to start measurement

.

6. Move the thermometer smoothly over the forehead to the other 

    temple and back

.

7. The measured value appears on the display and the end of the 

    measuring is signalled by a short beep

.

8. The thermometer will shut off automatically after 60 seconds 

     of inactivity. To prolong battery life, press the     

 BUTTON

  to 

     turn the unit off.

After self-checking, Figure 1 appears on the display screen with

    beeps, so you can start a new measurement.

How to switch between ear and forehead mode:

● 

When the device is on, Press and hold the 

S BUTTON

 to switch 

     between ear mode and forehead mode. 

● 

● 

Remove hat and hair and wait 10 minutes before taking a reading.

Do not use the thermometer on a perspiring or sweating forehead,

    as this may affect the reading. 

The temperature of a healthy person is affected by various factors: 

the person’s individual metabolism, their age(body temperature is 

higher in babies and toddlers and decreases with age. Greater 

temperature fluctuations occur faster and more often in children,

e.g. due to growth spurts), their clothing, the ambient temperature, 

the time of day(body temperature is lower in the morning and 

increases throughout the day towards evening), the preceding 

physical and, to a lesser extent, mental activity.

It is suggested that users develop the habit of daily measurement, 

and use this product to establish a private normal temperature 

range for themselves and their families as a reference for 

measurement.

Summary of Contents for DET-215

Page 1: ...r temperatures unsupervised some parts are small enough to be swallowed 4 Never immerse this device in water or other liquids not waterproof 5 Do not modify this equipment without authorization of manufacturer 6 Do not expose the thermometer to temperature extremes below 25 13 or over 55 131 nor excessive humidity 95 RH 7 Keep the battery away from children 8 The devices are reusable for home use ...

Page 2: ... the body temperature It can help you to monitor if the object temperature is suitable for the baby or patient for example the baby s milk Please see the section to learn how to measure the object temperature Illustration For Use The real time clock will be recorded with the memory function and help you to recognize each measurement result Please see the Real time clock setting section to learn ho...

Page 3: ...meter and the display is activated to show all segments 3 4 Place the probe with the forehead cap fitted on the temple 5 Press the START BUTTON to start measurement 6 Move the thermometer smoothly over the forehead to the other temple and back 7 The measured value appears on the display and the end of the measuring is signalled by a short beep 8 The thermometer will shut off automatically after 60...

Page 4: ...e end of the 1 Press the button to switch on the thermometer 2 Hold down the BUTTON and the S simultaneously for 2 seconds to switch to object temperature mode appears on the LCD display 3 Aim the thermometer at the center of the object you want to measure with a distance of 1 to 2 cm 4 Press the START BUTTON to start measurement 5 The measured value appears on the display and the end of the measu...

Page 5: ...o ensure that the reading always reflects the body temperature accurately you need to take account of the following factors which may affect an accurate reading 1 It is important to know each individual s normal temperature when they are well This is the only way to accurately diagnose a fever To determine normal temperature take multiple readings when healthy Re measure with a standard digital th...

Page 6: ...ing after using For cleaning 1 Soak a clean soft cloth in drinking water wring it out and then wipe the thermometer including probe no less than 3 times 2 Then use another clean soft cloth to wipe the residue water on thermometer 3 Put the thermometer in the original packaging For disinfection 1 Soak a clean soft cloth in drinking water wring it out and then wipe the thermometer including probe no...

Page 7: ... of the device which are required by the scope of relevant laws directives or ordinances where the device is used A clinical summary and procedures for checking calibration are available upon request Turn on the thermometer and press the power button long time until entering into calibrate mode software version will be displayed ASTM laboratory accuracy requirements in the display range of 36 0 to...

Page 8: ...s been tested and found to comply with the limits for a Class B digital device pursuant to Part 15 of the FCC Rules These limits are designed to provide reasonable protection against harmful interference in a residential installation This equipment generates uses and can radiate radio frequency energy If this equipment does cause harmful interference to radio or television reception which can be d...

Page 9: ...quency range 80 MHz to 2 7 GHz are intended to decrease the likelihood that mobile portable communications equipment could cause interference if it is inadvertently brought into patient areas For this reason an additional factor of 10 3 has been incorporated into the formulae used in calculating the recommended separation distance for transmitters in these frequency ranges c Field strengths from f...

Page 10: ...hone transceiver or radio control products If you have to do so the device should be observed to verify normal operation The use of accessories and power cord other than those specified with the exception of cables sold by the manufacturer of the equipment or system as replacement parts for internal components may result in increased emissions or decreased immunity of the equipment or system 35 36...