Shield 1500 Owner’s Manual
DOCXXX Rev 1
©Puralytics 2017
Page 26
Chapter 8: Other Maintenance
Introduction
Beyond ordinary regular maintenance items, some additional maintenance may arise. If
not found in this manual, contact Puralytics for additional assistance.
Power Input AC Fuse Replacement
1.
Disconnect power to Shield 1500
.
2. Locate the power input module (described above
and shown in Figure 5). The AC fuse is the
center piece located between the on/off switch
and the power receptacle.
3. Use a flathead screwdriver to unclip the top
bracket on the fuse holder (top image in Figure
19).
4. Use the same screwdriver to unclip the bottom
bracket on the fuse holder (middle image in
Figure 19) and pull the fuse towards you.
5. Grab the fuse holder with your fingers (bottom
image in Figure 19) to remove it.
6. A burnt fuse will appear dark/discolored. Dispose
of any burnt fuse.
7. A spare fuse is located in the fuse holder. Place it
where the burnt fuse was located.
8. Push the fuse holder back into place.