PUPPYOO WP609 Instruction Manual Download Page 6

Cautions

The product is with UV germicidal lamp, please do not view the bottom of the vacuum cleaner when 

the power supply and ultraviolet radiation sterilization function is switched on, otherwise it may 

damage human.
Please do not illuminate the animals with ultraviolet rays, it may damage the animal.
Don't illuminate one place continuously, it may cause damage while cleaning object.
When open the ultraviolet germicidal lamp, do not look in the UV light, do not expose skin under the 

UV light to avoid damage.

When open the ultraviolet germicidal lamp, do not use strong light or sunlight shine the light-sensi-

tive components of bottom of the machine to avoid to cause function malfunction which will affect 

the normal use of products and life or damage on human and animals.

1.3 Personal Security

This appliance can be used by children aged from 8 years and above and persons with reduced 

physical, sensory or mental capabilities or lack of experience and knowledge if they have been given 

supervision or instruction concerning use of the appliance in a safe way and understand the hazards 

involved. Children shall not play with the appliance. Cleaning and user maintenance shall not be 

made by children without supervision.

1.4 Product Safety Instruction

Power

This product is suited to 100V alternating current, do NOT use it under other power level.
Always check the power cord before use, the power cord and the plug should be in a good
condition and must NOT be damaged. If the power supply cord is damaged or detective. It must 

be replaced by the manufacturer, its service agent or similarly qualified persons in order to avoid 

a hazard.
Please don’t use this appliance any more if the power cord or plug got damage.
Do NOT handle or operate the appliance with wet hands and follow electrical safety precautions 

at all times.
Before carrying out any maintenance service or cleaning the filters, always switch off the cleaner 

and disconnect the plug from the mains power supply. The plug must be removed from the 

socket-outlet before cleaning or maintaining the appliance.

Range of Application

This appliance is used for home only, so please don’t use it in factory or business places.
To prevent unnecessary wear on the cleaning head, cleaning nozzle and damage to the
mattress, keep it moving while in operation.
Do NOT operate the mattress cleaner too close to heaters, radiators and other hot surfaces.
NEVER clean the mattress cleaner or any of the electrical parts, especially the electrical
connections with water or liquid cleaners.
Do NOT use the appliance to pick up flammable items or harmful liquids (i.e. gasoline, hot ashes, 

cigarettes, matches, explosive materials or anything burning) or use in areas where such 

substances and items may be present.
Do NOT use the appliance to clean the toner the laser printer or copier to avoid fire happen

02

Summary of Contents for WP609

Page 1: ...WP609 UV Mattress Vacuum Cleaner Instruction Manual...

Page 2: ...of the strong power for PUPPYOO and it just like at the moment start your spots car By the way the place of the handle is close to the air outlet as same as the other handheld UV mattress vacuum clea...

Page 3: ...for mattress and pillows cleaning Kill mites with high efficiency Double filtration high efficient filtering Simple and practical Prevent UV leakage safely and efficiently It can shake out dust mites...

Page 4: ...struction 2 Product Composition 03 2 1 Product Configuration 2 2 Components List 2 3 Name and Picture of Components 3 Operation Instruction 04 3 1 Before Using the Appliance 3 2 Operating Instruction...

Page 5: ...should be used for mattress cleaning only do NOT use it to clean construction waste or heavy metal dust Cautions Remind you about danger to the person Reminder Remind you about the damage to the appl...

Page 6: ...e it under other power level Always check the power cord before use the power cord and the plug should be in a good condition and must NOT be damaged If the power supply cord is damaged or detective I...

Page 7: ...s List Machine Body Instruction Manual Dust Container Components It has installed in the main body Notice Before Assembling please check the components according to the list 2 Product Composition WP60...

Page 8: ...proof Device Air Outlet Roller Wheel Power Cord Outlet Pressure sensitive Leak proof Device3 Vibration Flapping Plate2 ON OFF Button1 2 3 Personal Security 3 1 Before Using the Appliance 3 1 Before Us...

Page 9: ...void the water or reagent getting into the machine 4 3 Dust Container and HEPA Cleaning 1 Press the groove of the dust container Picture1 a and pull up the container gently 2 Hold the dust container w...

Page 10: ...SON The ON OFF button doesn t switch on SOLUTIONS Switch the button on UV lamp not work Excessive Noise REASON Pressure sensitive leak proof device is not contact with object SOLUTIONS The UV lamp wil...

Page 11: ...6 Parameter Type UV Mattress Vacuum Cleaner Model WP609 Voltage 100V 50Hz Rated Power 400W UV Lamp 15W 175mm Operation Radius 4m Dust Capacity 0 5L N W 1 58kg 07...

Page 12: ...environment and human health This will contribute to the recycling and other forms of reutilization of electrical and electronic equipment Information concerning where the equipment can be disposal o...

Reviews: