OWNER’S MANUAL
-13-
PNR-YF-05Y-A1
C. Output current not to rated value
:
When power voltage departs from the rated value, it will make the output current not matched with rated value;
When voltage is lower than rated value, the max output may lower than rated value.
D. Current is not stable when machine is being operated
:
It has something with factors as following:
1. The power net voltage has been changed.
2. There is harmful interference from power net or other equipment.
E. Serious splashing in MMA welding:
May be the welding current is too big, while the electrode diameter is too small;
The output terminal polarity is reversed, should use an anti- polarity under ordinary weld process, namely the
Electrode that should connect to the “+” terminal, but the work piece should connect to the “-” terminal, please
transpose the polarity.
TROUBLESHOOTING AND FAULT FINDING
TIG 315/400PAC/DC fault symptom and solutions.
Faults symptom
Solutions
Power indicator is not lit, fan
does not work and no welding
output
1. Power switch is damaged.
2. Make sure the electric wire net connecting to input cable is working alright
3. Make sure if input cable has broken circuit.
Power indicator is lit, fan is
working, The button on the
welding torch has no effect
1. Check if components are poor connects.
2. Check if connector of output terminal is break circuit and poor connect.
3. The control board is damaged. (Contact with dealer or manufacturer).