12 VDC Sump Pump

System Solid State Pump Controller

Power Supply Requirements  

12 VDC

Motor 

Brushless DC

AMP Rating 

18 Amps

Temperature Rating 

40°F to 120°F

Discharge 

1 1/2” NPT

MAX Flow 

3000 GPH

Power Supply Requirements  

 120 VAC, 60 Hz, 
15 AMP

Electrical Ratings 

 

12Amps @ 120 VAC; 
18 Amps @ 12 VDC

Relative Humidity 

0 to 80%

Storage Temperature 

0° to 70°C

Operating Temperature 

0° to 50°C

SPECIFICATIONS

PumpSpy

 PS2000

PumpSpy Technology | [email protected]

34000 Lear Industrial Parkway,  Avon, OH 44011

®

PUMP

SPY

The PumpSpy System requires a 12V Deep Cycle Battery (not included), 40 amp/hr 

minimum, 75 amp/hr or higher recommended. SLA/AGM Battery strongly recommended.

WIFI CONNECTED BATTERY BACKUP

 

SUMP PUMP & MONITORING SYSTEM

24/7 AUTOMATED REMOTE SUMP PUMP MONITORING

Summary of Contents for PS2000

Page 1: ...id State Pump Controller Power Supply Requirements 12VDC Motor Brushless DC AMP Rating 18 Amps Temperature Rating 40 F to 120 F Discharge 1 1 2 NPT MAX Flow 3000 GPH Power Supply Requirements 120VAC 60 Hz 15 AMP Electrical Ratings 12Amps 120VAC 18 Amps 12VDC Relative Humidity 0 to 80 Storage Temperature 0 to 70 C Operating Temperature 0 to 50 C SPECIFICATIONS PumpSpy PS2000 PumpSpy Technology supp...

Page 2: ...nected power cords with wet hands WARNING The PumpSpy System has not been investigated for use in or around swimming pools marine areas recreational water installations decorative fountains or any installation where human contact with the pumped fluid is common WARNING Do not use an extension cord Extension cords could present a safety hazard if not properly sized become damaged or the connection ...

Page 3: ...gure 1 1 The backup pump has a 1 1 2 in NPT discharge 2 Cut a 3 ft section of 1 1 2 in rigid PVC pipe Glue 1 1 2 in pipe to a threaded fitting 3 Screw pipe from step 2 into pump discharge 4 Place the pump with the 3 ft section of PVC pipe on a solid level surface in the sump pit Do NOT place the pump on a loose or sandy surface Small stones or sand may damage the pump resulting in pump failure 5 A...

Page 4: ... pump as shown in illustration for Method 2 8 Glue a short piece of PVC pipe between the 45º elbow and the Y THE CHECK VALVES FOR BOTH PUMPS MUST BE INSTALLED BELOW THE Y FITTING The remainder of the discharge pipe installation will vary depending on individual circumstances Using sound plumbing practices route the discharge pipe to an exterior wall by the shortest distance AFTER PLUMBING IS COMPL...

Page 5: ...e Red to positive Replace and lock lid onto battery case 8 Plug the PumpSpy controller into an AC outlet Consult your local codes for GFCI requirements 9 The PumpSpy system will initialize and boot up After booting MAIN PUMP BACKUP PUMP WIFI should be YELLOW WATER LEVEL POWER BATTERY should be GREEN MAIN PUMP BACKUP PUMP will turn GREEN after a successful test cycle TEST THE SYSTEM IN THIS ORDER P...

Page 6: ... yellow setup mode If the WiFi LED is not yellow gently press and hold the WiFi setup button using a pencil paper clip The unit will turn yellow enter setup mode after 3 seconds STEP 4 Connect to the PumpSpy System On your Apple Android device open Settings Select WiFi Select the WiFi network named PumpSpy Press the home button on your Apple Android device STEP 5 Enter your WiFi Network Credential...

Page 7: ... dark and a message will be displayed Close your browser Your PumpSpy devices Wi Fi indicator will turn red for several seconds then green once successfully connected to PumpSpy s servers If it stays red after 60 seconds start over Make sure you enter the correct Wi Fi password Once the Wi Fi indicator is green open the PumpSpy app and select Connect Device Manually Enter your PumpSpy device s 15 ...

Page 8: ... warranty service cost of shipping will be paid one way This warranty does not cover products purchased from a party that is not an authorized retailer dealer or distributor of PumpSpy products OTHER IMPORTANT TERMS This warranty is not transferable and may not be assigned This warranty shall be governed and construed under the laws of the state of Ohio The warranty period will not be extended by ...

Reviews: