the MESEP digital works without problems.
•
Red LED „VALVE FAULT“
After the last metal detection the separating drum did not reach the end
position. The MESEP digital can not separate the detected material. As soon as
the separating drum switches perfect again after a further metal detection, the
error report goes out automatically.
Elimination of “VALVE FAULT“
•
Put the reset key
•
Check the compressed air supply and compressed air height
•
Check separating drum on swinging
•
Red LED RING FAULT
Indicates a fault of ring coil or evaluation electronics. After elimination of the fault,
the LED goes out automatically, and the device is ready for operation again.
Elimination of “RING FAULT”
•
Remove power conducting matters being trapped in the ring coil.
•
Check electrical connections of the circuit board.
•
Inspect the metal separator visually.
•
Press the reset key.
•
Red LED PRESSURE FAULT
Indicates a fault of the compressed-air supply. This is an extended function and not
implemented in the basic variant.
Elimination of PRESSURE FAULT
•
Check the compressed-air supply.