Select the “Powerline Interface Module” as the 

Interface

 and 

then press the “

Find UPB Interface port

” button.  UPStart will 

automatically find the Communication Port that the PIM-R is 

connected to.  Next, press the “

Connect

” button to have 

UPStart connect and test the PIM-R. 

 

Signal & Noise Meters

 

Once connected, the PIM-R will constantly send reports to 

UPStart as to what is currently happening on the powerline.  

You can get a peek into the results of these reports by pressing 

the 

Signal & Noise Meters

 button to bring up the UPB 

Interface Diagnostics shown below. 

 

The meters will display a real-time indication of what the PIM-

R is reporting.  UPStart will also classify the reports as either 

“Signal” or “Noise” and display them on the proper meter.  

The meters are very useful for troubleshooting problems on 

the powerline. 

Status LED Indications 

The PIM-R contains a bi-color (blue/red) Status LED that will 

also give a visual indication of what UPB information is 

currently on the powerline.   

Blue: 

No UPB Signal 

Magenta: 

Received a UPB Message 

Red: 

Transmitted a UPB Message 

 

Push-button 

The push-button on the front of the PIM-R is used to put the 

device back to its factory default condition.  To set the PIM-R back 

to factory defaults first press the pushbutton 

5

 times rapidly.  The 

Status LED will blink blue.  Next, press the pushbutton 

10

 times.  

The Status LED will blink red.  Finally, press the pushbutton 

2

 

times.  The Status LED will stop blinking.  The device is now 

restored to its factory default state. 

 

CONFIGURATION 

The PIM-R has an adjustment for UPB receive sensitivity.  The 

factory default for this setting is “High”.  If the PIM-R is to be used 

in severe powerline noise, you may find that it operates better in 

the “Low” receive sensitivity setting. 

 

To adjust the receive sensitivity press the “Settings” button on the 

UPB Interface Setup dialog.  Next, select the desired receive 

sensitivity setting and press the “OK” button. 

 

 

 

 