BUILDING A SERIAL DMX CHAIN

 

Note: the DMX-output of the first fixture in the DMX chain with the DMX-input of 

the next fixture. Always connect one output with the input of the next fixture until all 

fixtures are connected.

 

Maximum recommended serial data link distance: 1640ft

 

Caution: At the last fixture, the DMX-cable has to be terminated with the 

terminator. Solder a 200Ω resistor between Signal (-) and Signal (+) into a 3-pin 

XLR plug and plug it into the DMX output of the last fixture.

DMX MASTER-SLAVE MODE

 

If you are using a controller with this fixture, you can connect the DMX-output of 

the controller directly with the DMX-input of the first fixture in the DMX chain. If you 

wish to connect a DMX-controller using other XLR socket types you need to use an 

adapter cable.

DMX CONTROLLER MODE

 

Other LED lights operating as slaves will work synchronously when connected in a 

chain using DMX cables.

DMX ADDRESS SETTINGS

 

Each light should be set with a particular starting address code. According to the 

actual requirements, users can either set multiple lamps with the same address 

code, or set each lamp with an independent address code.

 

Setting multiple lamps with the same address code means all connected lamps will 

be controlled together.

 

Setting each lamp with a different address code means the next light’s DMX 

address is dependent on the light’s DMX channels. 

 

This product has 6 DMX channels. For example the DMX address for the first light 

is 1, the DMX address for the second light should be 7 (1+6x1), the DMX address 

for the third light should be 13 (1+6x2) and so on.