background image

3

Installation Instructions

Thank you for choosing the Kauai III Rain Shower System by PULSE ShowerSpas!

Assembly and installation of the Kauai III Rain Shower System is 
designed to be quick and easy. If you have installation questions 
or performance problems, call PULSE Customer Service toll free at 
888-785-7320 or visit www.pulseshowerspas.com.

Please read instructions carefully, become familiar with all parts, 
installation procedures and tools required. Follow steps in order 
presented to help avoid mistakes.

FOR NEW CONSTRUCTION OR  

COMPLETE REMODEL

 

A hot/cold mixing valve is required (NOT INCLUDED)

 

 Nipple should extend 

1

2

" past finished wall surface.

TOOLS REQUIRED

 

Adjustable wrench, Phillips screwdriver, pencil, 2.5mm hex 
wrench, 3mm hex wrench

ASSEMBLY

  1.  Determine length of brass NPT nipple (1) needed:

a.  Place mark on existing shower arm at wall surface.  

Unscrew shower arm from elbow in wall.

b.  Measure distance from mark on shower arm to end of 

shower arm threads. Add 

1

2

" to this measurement, and 

then round to nearest 

1

2

".

Example 1: If measurement = 1

1

4

", add 

1

2

" = 1

3

4

",  

rounded = 2" NPT nipple—this is the length needed.

Example 2: If measurement = 1

5

8

", add 

1

2

" = 2

1

8

",  

rounded = 2" NPT nipple—this is the length needed.

IMPORTANT: 

If shower arm is located above tile/fiberglass wall 

surface you must add distance from sheetrock to face of tile/
fiberglass shower wall to the above measurement.

NOTE: 

If supplied 2" nipple (1) is not correct length based on 

above formula, you must obtain correct size NPT brass nipple 
(sold separately), available at most hardware stores.

  2.   Apply generous amount of PTFE Thread Sealant Tape (24) to 

both ends of nipple (1).

  3.   Hand tighten inlet fitting (2) onto nipple (1), then nipple 

to fitting in wall. Use adjustable wrench on inlet fitting 
to tighten both connections simultaneously until both are 
secure with no leaks.

  4.   Slide hand shower holder (9) off shower pipe (7).

  5.   Slide soap dish (8) onto shower pipe to desired position and 

secure with set screw (25).

        

CAUTION—

DO NOT OVERTIGHTEN

  5.   Reinstall hand shower hanger (9).

  6.  Insert rubber washer (21) into top of swivel joint (18) and       
        secure onto bottom of diverter body (12). Swivel joint should  
         move freely side to side.

         

CAUTION—

DO NOT OVERTIGHTEN

  7.   Insert shower pipe (7) into top tee (4). Secure with set screw 

(17).

 

8.   Slide top escutcheon (3) over top tee (4). 

         

HINT—

Lubricate escutcheon o-ring; a small amount of     

                       soapy water will do the trick. 

  9.   Slide bottom escutcheon (13) over diverter body (12).

         

HINT—

Lubricate escutcheon o-ring; a small amount of     

                       soapy water will do the trick.   

10.   Loosen set screw (20) on diverter and slide lower mount (15) 

into diverter body (12).

 11.   Push top tee (4) over inlet fitting (2) until flush against fit-

ting. Position diverter body (12) so shower pipe is plumb 
(vertical).

 12.   Mark location of lower mount with pencil.

 13.   Wall surface must be clean of any residue and completely 

dry. Remove covering of two-face tape and reposition  
lower mount (15) to mark with optional mounting holes. 
Ensure optional mounting holes are horizontal.

 14.   Apply pressure to mount for 30 seconds by pushing firmly 

against the diverter. To ensure proper adhesion, allow one 
hour before using your ShowerSpa and keep area around 
the mount as dry as possible for the first 24 hours. Tape will 
be fully cured after 24 hours.

OPTIONAL: 

Secure lower mount with permanent wall anchors. 

Mark hole locations in lower mount (15). Drill 1

1

4

" deep 

holes using 6mm (

1

4

") masonry/tile drill bit. Insert wall an-

chors (16) and secure lower mount with screws (14). 

CAUTION—

LIVE PLUMBING IN WALL

 15.   Position shower pipe (7) parallel to wall by sliding diverter 

body (12) on lower mount (15). Secure diverter to lower 
mount with set screw (20).

 16.   Insert rubber washer (21) into both ends of hose (11). Con-

nect hex head end to swivel joint (18) and tapered end to 
hand shower (10). Place hand shower (10) into adjustable 
hanger (9).

 17.   Insert rubber washer (21) in shower head (6) and tighten 

securely to shower arm (5).

Reviews: