background image

000

000

 1.  

Valve Body

  2-8. Integral Stop/Shuto

  Assembly

  9.  Pressure Balanced Cartridge
 10.  Limit Stop
 11. Valve Sleeve
 12. Trim Sleeve
 13.  Trim Nut
 14.  Valve Handle
 15.  Set Screw
 16.  Set Screw Cover
 17.  Friction Ring  
 18.  Trim Plate 
 19.  Plaster Guard
 20. Tub Spout Cap
 21. Wall Gasket/ Sealer
 22. Hot Water Inlet
 23. Cold Water Inlet
 24. Water Power Generator
 25. Tub Spout Outlet
 26. LED Display
 27. Water Power Generator
 28. Gasket
 29. LED Connector
 30. Snap On LED Housing

Parts Legend

Installation 

Valve Installation/Replacing Existing Valve

1.  TURN OFF WATER SUPPLY TO SHOWER. Typically there is a gate valve where the water main enters the 

house. Turning the water valve o

   at hot water tank does not turn o

   cold water supply line.

 2.   Make certain water is completely turned o

   to both hot & cold supply lines of shower. Turn shower valve 

on, both hot and cold, to VERIFY WATER SUPPLY IS OFF. Open a sink faucet in bathroom in which you are 

installing valve to relieve any pressure and help adequately drain shower supply lines.

 

3.  Remove handle(s) and trim cover(s) of your existing shower valve, exposing valve body in wall.

 4.   Locate hot and cold supply lines entering valve. Using a reciprocating saw with sharp metal saw blade and cut 

existing valve out. You should also cut riser within wall supplying existing shower head. Carefully twist and 

remove valve.

 5.  Install valve, MAKING SURE WATER POWERED GENERATOR AND "UP" OUTLET IS FACING UP and secure 

      to wall framing with screws (not included). Plaster guard (19) must be 

fl

 ush with 

fi

 nished wall for 

      proper positioning. Connect water supplies to valve (hot water to left side and cold water to right side). 

      Use thread seal compound or plumber's tape on all threaded connections to prevent leaks. 

      Some soldering of joints and 

fi

 ttings may be necessary for copper pipes.

 6.  Connect riser pipe and tub spout outlet plumbing. If you have a shower only model, you will need to cap  

 

      valve's tub outlet with supplied cap (20). Likewise if you have a tub only model, you will need to cap valve's 

      shower outlet. Do not attach showerhead until after 

fl

 ushing the shower's riser pipe. 

 7.  Step 1: Remove black gasket (28). 
       Step 2: Lift to release side lock and separate LED box and snap on LED housing (30). 
      Step 3: From the front of the trim (18) insert connector cable (29) and LED display (26) 

      through the trim LED window. NOTE: Make sure the circles on the LED Display (26) are facing down.
      Step 4: Place gasket (28) on the back of the trim (18) onto LED display (26). 
      Step5: Place snap on LED housing (30) onto LED display (26) through the back and snap on to lock in place.
      Step 6: Connect LED display (26) to water power generator (24) on valve.
     

  8. Remove plaster guard (19). Install nylon friction ring (17) and wall gasket (21) to trim plate (18). Align trim 

plate with LED display and slide over valve assembly. Install handle (14)  and tighten set screw (15).

NOTE: Make sure you follow the UP and DOWN arrows on the valve body (1) for correct placement.

000

Cold water at 78°F and below

Warm water at 79°F to 96°F

Hot water at 97°F and above

Summary of Contents for 3002-RIV-PB-BN

Page 1: ...se repaired or replacement Products will continue to be covered under this warranty for as long as he or she owns that same home For other purchasers repaired or replacement Products will be covered for the balance of the original warranty period 5 No Other Warranties Limitation of Liability OTHER THAN THE LIFETIME LIMITED WARRANTY STATED ABOVE PULSE DISCLAIMS ALL OTHER WARRANTIES EXPRESS OR IMPLI...

Page 2: ... Valve This valve is equipped with a cUPC Tru Temp pressure balance mixing cartridge to adjust water flow and temperature The valve automatically adjusts to changes in water pressure i e someone flushes a toilet keeping your temperature constant preventing accidental scalding To turn on the water simply raise the handle until the desired flow rate is achieved Rotate handle right to decrease temper...

Page 3: ...e in the system 1 Loosen set screw 15 with an allen wrench and remove valve handle 14 2 Remove cartridge trim nut 13 and trim sleeve 12 by hand 3 For a lower temperature pull red limit stop 10 out with needle nose pliers turn it counter clockwise and push it back onto cartridge 4 For a higher temperature pull red limit stop 10 out with needle nose pliers turn it clockwise and push it back onto car...

Page 4: ...TLET IS FACING UP and secure to wall framing with screws not included Plaster guard 19 must be flush with finished wall for proper positioning Connect water supplies to valve hot water to left side and cold water to right side Use thread seal compound or plumber s tape on all threaded connections to prevent leaks Some soldering of joints and fittings may be necessary for copper pipes 6 Connect ris...