background image

 

2.  Installation 

2.1. Requirements 

1. The device should be mounted by a qualified installer, holding relevant permits and licenses (applicable and  required  
for  a  given  country)  for  230V/AC  and  low-voltage  installations.  
2.  The  device  shall  be  mounted  in  confined  spaces,  according  to  the  environment  class  II,  with  normal  air  humidity 
(RH=90% max. without condensation) and the temperature from -

10°C to +40°C.  

3. The switch shall work in a vertical position that guarantees sufficient convectional air-flow through ventilating holes of 
the  enclosure.  Before  installation,  prepare  a  Switch'a  load  balance.  The  given  value  of  30W  per  port  is  the  maximum 
value  referring  to  a  single  output. 

The  total  power  consumption  should  not  exceed  48W  when  all  PoE  ports  are 

being  used

.  The  increased  demand  for  power  is  particularly  evident  in  the  case  of  cameras  with  heaters  or  infrared 

illuminators - when launching these features, the power consumption increases rapidly, which may adversely affect the 
operation of the switch. As the device is designed for a continuous operation and is not equipped with a power-switch, 
therefore an appropriate overload protection shall be guaranteed in the power supply circuit. Moreover, the user shall be 
informed about the method of unplugging (usually through assigning an appropriate fuse in the fuse-box). The electrical 
system shall follow valid standards and regulations. 

 

2.2.  Installation procedure 

1. Before installation, cut off the voltage in the 230V power-supply circuit. 
2. Mount the PSU in a selected location and connect the wires.  
3. Connect the power cables (~230Vac) to L-N clips of the PSU.  

 

 

The shock protection circuit shall be performed with a particular care, i.e. the yellow 

and green wire coat of the power cable shall stick to one side of the terminal - marked 

with ‘

 symbol on the PSU enclosure. Operation of the PSU without the properly 

made and fully operational shock protection circuit is UNACCEPTABLE! It can cause a 

device failure or an electric shock

.

 

4. Connect the ground wire to the terminal marked with the 

 symbol (power supply module connector). Use a three-

core cable (with a yellow and green PE protection wire) to make the connection. Lead the cables to the appropriate clips 
through the insulating bushing of the connection board.  
5. Connect the power (~230V).  
6. Connect the camera cables to the RJ45 connectors (PoE connectors) 
7. Check the optical indication of the switch operation. 
8. After installing and checking proper working, the enclosure can be closed. 
 

         Connection schemes 
 

 

 
 
 

 

 

Reviews: