4.

 

Operation and use

 

 

4.1

 

Overload or short circuit of the PSU output (SCP on).

 

In case of overload, the output voltage is automatically shut off, and so is the LED indicator. The restoration of the voltage 

takes place immediately after the failure (overload) is over.  

 

4.2

 

Disconnection of discharged battery.

 

The PSU is equipped with the discharged battery disconnection system. During the battery-assisted operation, reducing 

voltage below 9,5V at the battery terminals will cause battery disconnection.  

 

4.3 Maintenance.

 

Any  and  all  maintenance  operations  may  be  performed  following  the  disconnection  of  the  PSU  from  the  power  supply 

network. The PSU   does not require performing any specific maintenance measures, however, in case of significant dust rate, 
its interior is recommended to be cleaned with compressed air. In case of fuse replacement, use a replacement of the same 
parameters.  

 

 

 

WEEE LABEL 

 
Waste electrical and electronic equipment must not be disposed of with normal household waste. 

According  to  the  European  Union  WEEE  Directive,  waste  electrical  and  electronic  equipment 
should be disposed of separately from normal household waste

 

 

 

The power supply unit is adapted for a sealed lead-acid battery (SLA). After the operation period it must not be disposed of but recycled according to the 

applicable law.

 

 

 
 

 

 
 
 
 
 
 
 
 
 

 

 
 
 
 
 
 
 
 
 
 
 
 
 

 
 
 

Pulsar  

Siedlec 150,  32-

744 Łapczyca, Poland 

Tel. (+48) 14-610-19-40, Fax. (+48) 14-610-19-50 

e-mail

[email protected]

[email protected]

 

http:// 

www.pulsar.pl

www.zasilacze.pl

 

 

 

Summary of Contents for SG64-B

Page 1: ...re color white RAL 9003 with battery space for a 7Ah 12V battery Supports auto learning and auto aging of MAC addresses 1K size warranty 2 year from the production date Example of use CONTENTS 1 Techn...

Page 2: ...up time assumptions for calculations Automatic detection of any devices powered in the PoE PoE standard is enabled at the 1 4 ports of the switch The UP LINK ports is used for connection of another ne...

Page 3: ...witch PoE 2 Switch mode buffer power supply unit 3 DC DC52115 converter 4 Output filter 5 Tamper micro switch terminals of tamper protection NC 6 Battery space for a 7Ah 12V 7 Power supply connector o...

Page 4: ...ct PoE Status The given value of 30W per port is the maximum value The total power consumption should not exceed 48W when all PoE ports are being used Table 4 Electrical parameters Mains supply 176 26...

Page 5: ...10 C to 40 C The switch shall work in a vertical position that guarantees sufficient convectional air flow through ventilating holes of the enclosure Before installation prepare a Switch a load balan...

Page 6: ...onnector 8 Check the optical indication of the switch operation 9 After installing and checking proper working the enclosure can be closed Connection schemes 3 Indication of the device operation 3 1 L...

Page 7: ...IEEE802 3af at standard ON supply at the RJ45 port Blinking short circuit or output overload YELLOW LED LIGHT LINK The connection status of LAN devices 10MB s or 100Mb s and data transmission OFF no c...

Page 8: ...work The PSU does not require performing any specific maintenance measures however in case of significant dust rate its interior is recommended to be cleaned with compressed air In case of fuse replac...

Reviews: