background image

 

Short-circuit protection SCP and overload protection OLP 

105% ÷ 150% of power supply, manual restart 

 (the fault requires disconnection of the DC output circuit) 

PSU current consumption 

300mA/27,6V 

Battery charge current

 

1,0A max. /2x17Ah (+/-5%) 

Approximate backup time 

3h 15min 

Battery circuit protection SCP and reverse  
polarity connection 

melting fuse 

Deep discharge battery protection UVP  

U<19V (± 5%) – disconnection of the batteries 

Sabotage protection: 
- TAMPER output indicating enclosure opening 

 

- microswitch, NC contacts (enclosure closed), 

0,5A@50V DC (max.) 

 

 

 
Table 5. Mechanical parameters 

Dimensions 

W=397, H=350, D+D

1

=92+8 [+/- 2mm] 

W

1

=402, H

1

=355 [+/- 2mm] 

The dimensions of the 
battery compartment 

370 x 180 x 80mm (WxHxD) max   

Gross/Net weight 

5,5 / 5,8 kg 

Enclosure 

Steel plate, DC01 1,0mm color white RAL 9003 

Closing 

Cheese head screw x 2 (at the front), (lock assembly possible) 

Connectors 

Power supply of the cameras:  RJ45 socket 
Power supply  for recorder: DC2,1/5,5 plug 
Outputs: 

Φ 0,63-2,50 (AWG 22-10), 

Battery output BAT: 6,3F-2,5  
TAMPER output: wires  

Notes 

The enclosure does not touch the assembly surface so that cables can be led. 

 
Table 6. Operation safety 

Protection class EN 609501:2007  

I (first) 

Protection grade EN 60529: 2002 (U)  

IP20 

Electrical strength of insulation: 
- between input and output circuits of the PSU (I/P-O/P) 
- between input circuit and PE protection circuit (I/P-FG) 
- between output circuit and PE protection circuit (O/P-FG) 

 

3000 V/AC min. 
1500 V/AC min. 
  500 V/AC min. 

Insulation resistance: 
- between input circuit and output or protection circuit 

 

100 MΩ, 500V/DC 

Declarations 

CE 

 

Table 7. Operating parameters

 

Operating temperature 

-

10ºC...+40ºC 

Storage temperature 

-

20ºC...+60ºC 

Relative humidity 

20%...90%, without condensation 

Vibrations during operation 

unacceptable 

Impulse waves during operation 

unacceptable 

Direct insulation 

unacceptable 

Vibrations and impulse waves during transport 

According to PN-83/T-42106 

 

 

 

 

 

 

Summary of Contents for SG108-BR

Page 1: ...h 15min LED indication Metal enclosure color white RAL 9003 with space for two 17Ah 12V battery Supports auto learning and auto aging of MAC addresses 8K size warranty 2 year from the production date...

Page 2: ...of how to perform the calculations can be found at Approximate backup time assumptions for calculations Automatic detection of any devices powered in the PoE PoE standard is enabled at the 1 8 ports o...

Page 3: ...e buffer power supply unit 3 DC DC50SD converter 4 DC DC48250 converter 5 Output filter 6 Tamper micro switch terminals of tamper protection NC 7 Fitting battery 17Ah 12V 8 Power supply connector of t...

Page 4: ...1 8 ports 52V DC 30W at each port Used pairs 4 5 7 8 Protocols Standards IEEE802 3 802 3u 802 3x CSMA CD TCP IP Bandwidth 16Gbps Transmission method Store and Forward Optical indication of operation...

Page 5: ...possible Connectors Power supply of the cameras RJ45 socket Power supply for recorder DC2 1 5 5 plug Outputs 0 63 2 50 AWG 22 10 Battery output BAT 6 3F 2 5 TAMPER output wires Notes The enclosure doe...

Page 6: ...priate fuse in the fuse box The electrical system shall follow valid standards and regulations 2 2 Installation procedure 1 Before installation cut off the voltage in the 230V power supply circuit 2 M...

Page 7: ...1 LED indication of operating status The PSU is equipped with two diodes on the front panel RED LED on the PSU is supplied with 230V AC off no 230V AC supply GREEN LED on DC voltage in the AUX output...

Page 8: ...with the IEEE802 3af at standard ON supply at the RJ45 port Blinking short circuit or output overload YELLOW LED LIGHT LINK The connection status of LAN devices 10 10 1000 Mb s and data transmission...

Page 9: ...rged battery disconnection system During the battery assisted operation reducing voltage below 19V at the battery terminals will cause battery disconnection 4 3 Maintenance Any and all maintenance ope...

Page 10: ...ipment should be disposed of separately from normal household waste The power supply unit is adapted for a sealed lead acid battery SLA After the operation period it must not be disposed of but recycl...

Reviews: