5
3. Operation indication.
Table 3. Operation indication
OPTICAL INDICATION OF THE SWITCH's POWER SUPPLY
GREEN LED LIGHT (Power)
Indication of the switch's
power supply
OFF
– no power supply of the switch
ON
– power supply on, normal operation
OPTICAL INDICATION AT THE PoE PORTS (1
÷4)
GREEN LED LIGHT (PoE)
Indication of the PoE power
supply at the RJ45 ports
OFF
- no power supply at the RJ45 port (the device is not connected or not compliant
with the IEEE802. 3af/at standard)
ON
– supply at the RJ45 port
Blinking
– short-circuit or output overload
YELLOW LED LIGHT (LINK)
The connection status of LAN
devices, 10MB/s or 100Mb/s
and data transmission
OFF
- no connection
ON
- the device is connected; 10Mb/s or 100Mb/s
Blinking
– data transmission
OPTICAL INDICATION AT THE UP LINK PORTS
GREEN LED LIGHT
OFF
- no connection/ the device is connected; 10Mb/s
ON
– the device is connected; 100Mb/s
YELLOW LED LIGHT (LINK)
The connection status of LAN
devices, 10MB/s or 100Mb/s
and data transmission
OFF
- no data transmission
ON
- the device is connected; 10Mb/s or 100Mb/s
Blinking
– data transmission
WEEE LABEL
Waste electrical and electronic equipment must not be disposed of with normal household waste.
According to the European Union WEEE Directive, waste electrical and electronic equipment
should be disposed of separately from normal household waste.
Pulsar
Siedlec 150, 32-744 Łapczyca, Poland
Tel. (+48) 14-610-19-40, Fax. (+48) 14-610-19-50
e-mail:
Summary of Contents for S64
Page 4: ...4 Connection schemes ...