background image

 

2.  Installation 

2.1. Requirements 

1. The device should be mounted by a qualified installer, holding relevant permits and licenses (applicable and  required            
for  a  given  country)  for  230 V  and  low-voltage  installations. It is required to install an installation switch with a nominal 
current of min. 3 A in the power supply circuits outside the power supply unit.

 

2.  The  device  shall  be  mounted  in  confined  spaces,  according  to  the  environment  class  II,  with  normal  air  humidity 
(RH=90% max. without condensation) and the temperature from -

10°C to +40°C.  

3. The switch shall work in a vertical position that guarantees sufficient convectional air-flow through ventilating holes of 
the enclosure.  Before installation, prepare a  Switch'a load balance. The given value of 30 W per port is the  maximum 
value referring to a single output. 

The total power consumption should not exceed 48 W. 

The increased demand for 

power  is  particularly  evident  in  the  case  of  cameras  with  heaters  or  infrared  illuminators  -  when  launching  these 
features,  the  power  consumption  increases  rapidly,  which  may  adversely  affect  the  operation  of  the  switch.  As  the 
device  is  designed  for  a  continuous  operation  and  is  not  equipped  with  a  power-switch,  therefore  an  appropriate 
overload  protection  shall  be  guaranteed  in  the  power  supply  circuit.  Moreover,  the  user  shall  be  informed  about  the 
method of unplugging (usually through assigning an appropriate fuse in the fuse-box). The electrical system shall follow 
valid standards and regulations. 

 

2.2.  Installation procedure 

 

 

Before installation, cut off the voltage in the 230 V power-supply circuit. 

To switch power off, use an external switch, in which the distance between the contacts of all 

poles in the disconnection state is not less than 3mm. 

 

 
1. Mount the PSU in a selected location and connect the wires.  
2. Connect the power cables (230 V) to L-N clips of the PSU.  

 

The shock protection circuit shall be performed with a particular care, i.e. the yellow and green wire 

coat of the power cable shall stick to one side of the terminal - 

marked with ‘

 

 symbol on the PSU 

enclosure. Operation of the PSU without the properly made and fully operational shock protection 

circuit is UNACCEPTABLE! It can cause a device failure or an electric shock.

 

 

 

3. Connect the ground wire to the terminal marked with the 

 symbol (power supply module connector). Use a three-

core cable (with a yellow and green 

 protection wire) to make the connection. Lead the cables to the appropriate clips 

through the insulating bushing of the connection board.  
4. Connect the power (230 V).  
5. Connect the camera cables to the RJ45 connectors (PoE connectors). 
6. Check the optical indication of the switch operation. 
7. After installing and checking proper working, the enclosure can be closed. 
 

         Connection schemes 

 

 