S54 

v1.0 

The S54 5-port switch for 4 IP cameras 

 

 
 

                                                                                                                                                 

 

        PL 

               

 Edition: 2 from 22.02.2016 

Supercedes the edition: 1 from 01.09.2015 

EN** 

 

 

Features: 

 

 

5 10/100 Mb/s ports 

 

4 PoE ports (data transfer and power supply)  

 

15,4W for each PoE port, supports devices complaint 
with the IEEE802.3af standard 

 

Supports auto-learning and auto-aging of MAC 
addresses (1K size) 

 

LED indication 

 

  The PSD 480125 48VDC/1,25A/60W max. 

power supply desktop type included 

  Additional assembly elements 

  warranty 

– 2 year from the production date  

 

Example of use.

 

 

                                            

1.  Technical description

  

 

1.1. General description. 

            

S54 is a 5-port PoE switch designed to supply IP cameras operating in IEEE 802.3af standard. Automatic detection of 

any devices powered in the PoE standard is enabled at the 1 

– 4 ports of the switch. The UPLINK port is used for connection of 

another network device. The LEDs at the front panel indicate the operation status (description in the table below). 
The PoE technology ensures a network connection and reduces installation costs by eliminating the need to supply a separate 
power cable for each device. This method allows supplying other network devices, such as IP phone, wireless access point or 
router. 

          

1.2 Block diagram. 

 

Summary of Contents for S54

Page 1: ... date Example of use 1 Technical description 1 1 General description S54 is a 5 port PoE switch designed to supply IP cameras operating in IEEE 802 3af standard Automatic detection of any devices powered in the PoE standard is enabled at the 1 4 ports of the switch The UPLINK port is used for connection of another network device The LEDs at the front panel indicate the operation status description...

Page 2: ... diagram 1 3 Description of components and connectors Table 1 see Fig 2 Element no Fig 2 Description 1 4 x PoE port 1 4 2 1 x UPLINK port 3 Power Socket of the 48VDC Fig 2 The view switch a 1 4 Technical parameters ...

Page 3: ...h normal relative humidity RH 90 maximum without condensation and temperature from 10 C to 45 C Ensure the free flow of air around the unit The PSU shall work in a vertical position that guarantees sufficient convectional air flow through ventilating holes of the enclosure The load balance should be done before installation Switcha The given value of 15 4W per port is the maximum value referring t...

Page 4: ...4 Connection schemes ...

Page 5: ...r not compliant with the IEEE802 3af standard ON supply at the RJ45 port Blinking short circuit or output overload YELLOW LED LIGHT LINK The connection status of LAN devices 10MB s or 100Mb s and data transmission OFF no connection ON the device is connected 10Mb s or 100Mb s Blinking data transmission OPTICAL INDICATION AT THE UPLINK PORT GREEN LED LIGHT OFF no connection ON the device is connect...

Page 6: ...ossibilities to carry out the repairs or if the equipment has been conditionally accepted due to the breaking warranty terms by the claimant 7 All the services are carried out at the service centre of the manufacturer exclusively 8 The warranty does not cover the defects of the equipment resulting from reasons beyond the manufacturer s control mechanical damage improper storage and transport use t...

Reviews: