1.4. Technical parameters (Table 3.) 
 

       

Table 3. 

            

Ports 

5  10/100Mb/s ports (4 x PoE + 1 x UPLINK)                                                                                              

with connection speed auto-negotiation and MDI/MDIX Auto Cross) 

PoE power supply 

IEEE 802.3af (1

÷4 ports),  48V DC / 15,4W at each port   

Protocols, Standards 

IEEE802.3, 802.3u, 802.3x  CSMA/CD, TCP/IP 

Forwarding rate 

10BASE-T: 14880pps/port 

100BASE-TX: 148800pps/port 

Bandwidth 

1,6Gbps 

Transmission method 

Store-and-Forward 

Optical indication of 
operation 

Switch power supply; 

Link/Act; 

PoE Status 

Power supply 

90 ÷ 264VAC 50÷60Hz / 1,2A  230VAC 

Operating conditions 

temperature -

10°C ÷ 45°C,  

relative humidity  5% - 90%, no condensation 

Dimensions (W x H x D) 

Switch: 118 x 28 x 85 [mm] 

Enclosure: 190 x 115 x 102+14  [mm] 

Enclosure

 

Steel plate, DC01 1,0mm color RAL 9003 

Closing

 

Cheese screw x 1 (at the front)  

Notes 

The enclosure does not adjoin the assembly surface so that cables can be led 

Gross/Net weight 

1,92/2,05kg 

Protection class        
EN 60950-1:2007 

II (second) 

Storage temperatur 

-

20°C ÷ 60°C 

Declarations

 

CE 

 
 
 
 
 
 
 
 

Summary of Contents for S54-C

Page 1: ...h 1 Technical description 1 1 General description The S54 C is a complete kit to build the CCTV system based on IP cameras The switch is placed in a metal enclosure Automatic detection of any devices powered in the PoE standard is enabled at the 1 4 ports of the switch The UPLINK port is used for connection of another network device The LEDs at the front panel indicate the operation status descrip...

Page 2: ...ig 2 Element no Fig 2 Description 1 Switch 2 Switch mode power supply for the switch 48VDC 1 2A 60W 3 Potentiometer adjusting the output voltage of the power supply 46 52V 4 LED light power supply operation indication 5 F 6 3A 250V fuse socket 6 Mounting brackets for cables Fig 2 The enclosure view ...

Page 3: ... port 100BASE TX 148800pps port Bandwidth 1 6Gbps Transmission method Store and Forward Optical indication of operation Switch power supply Link Act PoE Status Power supply 90 264VAC 50 60Hz 1 2A 230VAC Operating conditions temperature 10 C 45 C relative humidity 5 90 no condensation Dimensions W x H x D Switch 118 x 28 x 85 mm Enclosure 190 x 115 x 102 14 mm Enclosure Steel plate DC01 1 0mm color...

Page 4: ...r supply circuit should be provided Moreover the user should be informed how to disconnect the power supply unit from the mains supply usually by assigning an appropriate fuse in the fuse box The electrical system shall be made in accordance with applicable standards and regulations 2 2 Installation procedure 1 Before installation make sure that the voltage in the 230V power supply circuit is cut ...

Page 5: ...r not compliant with the IEEE802 3af standard ON supply at the RJ45 port Blinking short circuit or output overload YELLOW LED LIGHT LINK The connection status of LAN devices 10MB s or 100Mb s and data transmission OFF no connection ON the device is connected 10Mb s or 100Mb s Blinking data transmission OPTICAL INDICATION AT THE UPLINK PORT GREEN LED LIGHT OFF no connection ON the device is connect...

Page 6: ...ossibilities to carry out the repairs or if the equipment has been conditionally accepted due to the breaking warranty terms by the claimant 7 All the services are carried out at the service centre of the manufacturer exclusively 8 The warranty does not cover the defects of the equipment resulting from reasons beyond the manufacturer s control mechanical damage improper storage and transport use t...

Reviews: