1.4. Specifications.
- electrical parameters (tab.2)
- mechanical parameters (tab.3)
- operation safety (tab.4)
- operating parameters (tab.5)
Electrical parameters (tab. 2).
Mains supply
230V AC (-15%/+10%) 50Hz
Current up to
1A max./230V AC
Supply power
192W max.
Efficiency
82%
Output voltage
24V DC
Voltage adjustment range output
2
0÷26V DC
Output current
16 x 0,5A (
I = 8A)
max. @24V
Ripple
150 mV p-p max.
Short-circuit protection SCP
16 x F 0,5A melting fuse
Overload protection OLP
105% ÷ 150% of the PSU power, automatic return
Overvoltage protection OVP
29,5 ÷ 35V (PSU restart required)
Surge protection
varistors
Optical indication of operation:
LED: AC, DC, TEMP,
ALARM, AUX1÷AUX16
Acoustic operation indication:
Piezoelectric indicator ~75dB/0,3m
The ALARM technical output of collective failure
Relay type: 1A@ 30VDC/50VAC
The
F
MAINS
fuse in the 230V power supply circuit
T 6,3A
F1 ÷ F16
, glass fuses in the cameras AUX (+)
power supply circuits
F 0,5A
Mechanical parameters (tab. 3).
Enclosure dimensions
W=19”, H=2U; 482 x 88 x 223 mm (WxHxD)
Fixation
four-point butt mounting to RACK profiles
– the set include 4 M6 cage nuts
Net weight
5,4kg / 5,9kg
Enclosure
Steel plate RAL 9005, black
Connectors
230V AC input: the IEC C14 socket with a fuse, power cable 1,5m
(included)
Outputs: BAT, ALARM,
AUX1÷AUX16: Φ0,5-2,1 (AWG 24-12) 0,5-2mm
2
Notes
Forced cooling (fan)
Operation safety (tab.4).
Protection class PN-EN 60950-1:2007
I (first)
Protection grade PN-EN 60529: 2002 (U)
IP20
Electrical strength of insulation:
- between input and output circuits of the PSU (I/P-O/P)
- between input circuit and PE protection circuit (I/P-FG)
- between output circuit and PE protection circuit (O/P-FG)
3000 V/AC min.
1500 V/AC min.
500 V/AC min.
Insulation resistance:
- between input circuit and output or protection circuit
100 MΩ, 500V/DC
Operating parameters (tab.5).
Environmental class
II
Operating temperature
-
10ºC...+45ºC
Storage temperature
-
20ºC...+60ºC
Relative humidity
20%...90%, without condensation
Vibrations during operation
unacceptable
Impulse waves during operation
unacceptable
Direct insulation
unacceptable
Vibrations and impulse waves during transport
According to PN-83/T-42106