background image

www.pulsar.pl

    

 

 

 

R1612T 

 

 

  

            

RACK POWER

 

 

2.2. Installation procedure. 

 

1. Before installation, cut off the voltage in the 230V power-supply circuit. 
2. Mount the power supply in a RACK 19" cabinet as shown below: 
 

 

- Mount M6 cage nuts 

 

- Secure the enclosure with 4xM6 screws 

 
3. Connect the receivers’ cables to the terminals AUX1...AUX16. 
4. If needed, the following technical connections can be made: 
- ALARM – technical output of collective failure 
5.  Connect  the  ~230V  AC  power  cord  with  the  IEC  C13  plug  (included)  to  the  230V  AC  power  supply  and  turn  on  the 
power (~230V). 
6. In the case of an unsafe voltage supply with frequent voltage drops in effective resistance of receiver supply cables 
can occur, it is possible to adjust the output voltage using the potentiometer (12V÷15V DC) at the front panel of the power 
supply. 
7. Check the PSU operation indicator. 

 

3.  Operating status indication. 
 

3.1.  LED indication. 
The PSU has 20 LED lights at the front panel: 
 

 

 
 

 

 
 

 

 
 

 

 
 
 

 

 
 

GREEN LED: 

 

on – the PSU is supplied with 230V AC 

 

off – no 230V AC supply 

 
GREEN LED: 

 

on – DC voltage at the output of the switch mode PSU 

 

off – no DC voltage at the output of the switch mode PSU 

 
RED LED: 

 

on – failure 

 

off – no failure 

 
 
RED LED: 

 

ON – too high temperature of the switch mode power supply 
(>70°C) 

 

OFF – standard temperature of the switch mode power supply 

 

 
GREEN LED: 

 

on – DC voltage in the AUX1…AUX16 output 

 

off – no DC voltage in the AUX1…AUX16 output 

 

 
 
 

Summary of Contents for R1612T

Page 1: ...R1612T v 1 0 R 12V 16x1 5A TOPIC RACK mounted power supply for up to 16 analog cameras EN Edition 1 from 28 01 2016 Supercedes the edition...

Page 2: ...activated by 230V AC power loss activation of the output fuse in the camera power supply circuit too high temperature of the PSU 70 C the PSU failure protections SCP short circuit protection OVP over...

Page 3: ...mounting in standard RACK 19 cabinets 1 2 Block diagram Fig 1 The block diagram of the PSU 1 3 Description of PSU components and connectors Table 1 Components of the front panel of the power supply El...

Page 4: ...230V AC max Supply power 168W max Efficiency 80 Output voltage 12V DC Voltage adjustment range output 12 15V DC Output current 16 x 0 87A I 14A max 12V Ripple 100 mV p p max Short circuit protection...

Page 5: ...00 M 500V DC Operating parameters tab 5 Environmental class II Operating temperature 10 C 45 C Storage temperature 20 C 60 C Relative humidity 20 90 without condensation Vibrations during operation un...

Page 6: ...ply with frequent voltage drops in effective resistance of receiver supply cables can occur it is possible to adjust the output voltage using the potentiometer 12V 15V DC at the front panel of the pow...

Page 7: ...A collective failure is indicated by the piezoelectric indicator 1 beep every second The acoustic indication can be turned off by changing the ON OFF position of the switch switch in the up position...

Page 8: ...e no technical possibilities to carry out the repairs or if the equipment has been conditionally accepted due to the breaking warranty terms by the claimant 7 All the services are carried out at the s...

Reviews: