Operating specifications (tab.6). 

Operating temperature 

-10ºC...+50ºC  

Storage temperature 

-25ºC...+60ºC 

Relative humidity 

20%...90%, without condensation 

Vibrations during operation 

unacceptable 

Impulse waves during operation 

unacceptable 

Direct insolation 

unacceptable 

Vibrations and impulse waves during transport 

PN-83/T-42106 

 
 
2. Installation. 
 

2.1 Requirements. 

The  stabilized  PSU  is  to  be  mounted  by  a  qualified  installer,  holding  relevant  permits  and  licenses 

(applicable  and  required  for  a  given  country)  for  230V/AC  interference  and  low-voltage  installations.  The  unit 
should  be  mounted  in  confined  spaces,  in  accordance  with  the  2nd  environmental  class,  with  normal  relative 
humidity (RH=90% maximum, without condensation) and temperature from -10°C to +50°C. The PSU shall work in 
a vertical position that guarantees sufficient convectional air-flow through ventilating holes of the enclosure. 
 

During normal operation the total current consumption of the receivers cannot exceed 

I=16x0,5A 

 
 

As  the  PSU  module  is  designed  for  a  continuous  operation  and  is  not  equipped  with  a  power-switch, 

therefore  an  appropriate  overload  protection  shall  be  guaranteed  in  the  power  supply  circuit.  Moreover,  the  user 
shall  be  informed  about  the  method  of  unplugging  (most  frequently  through  separating  and  assigning  an 
appropriate fuse in the fuse-box). The electrical system shall follow valid standards and regulations. 

 
 
2.2  Installation procedure. 

 

1. Before installation, make sure that the voltage in the 230V power-supply circuit is cut off. 

2. Mount the PSU in a selected location and connect the wires. 
3. Connect the power cables (~230VAC) to L-N terminals of the PSU. Connect the ground wire to the terminal 
marked by the earth symbol. Use a three-core cable (with a yellow and green PE protection wire 

) to make the 

connection. Lead the cables to the appropriate terminals of the connection board through the bushing. 

 

The shock protection circuit shall be performed with a particular care, i.e. the yellow 

and green wire coat of the power cable shall stick to one side of the terminal marked with the 

’ earth symbol in the PSU enclosure. Operation of the power supply without a properly 

made and fully operational shock protection circuit is UNACCEPTABLE! It can result in 
device damage or an electric shock. 

 

 
4. Connect the receivers’ cables to the 

AUX1…AUX8 

connectors

 

on the

 LB8/AW (A, B) strips. 

5. If necessary, connect the device’s wires (of an alarm panel, controller, indicator, etc.) to the technical outputs: 
     - 

FPS (LB8/AW A, B)

 output indicating a fuse failure (outputs of the LB8/AW A,B fuse strips). 

     - 

TAMPER 

output indicating unwanted opening of the PSU’s enclosure. 

6. In electrical installations with significant voltage drops in the resistance of the wires that lead to the receivers, the 
voltage value can be corrected with the P1 potentiometer (12V÷15V DC). 
7. Check the PSU operating status indication 
8. Once the installation and operation control have been completed, the enclosure can be locked. 

 

3. Operating status indication. 

The PSU is equipped with LED indication of operation status. The presence of power at the outputs of the 

PSU is indicated by the illumination of green LEDs on the front panel of the device. 

L

FPS

 red LED [!] indicates a 

failure. The status of the PSU can be remote controlled by the FPS technical output. 

 
 
 
 
 

Summary of Contents for PSDC 16128

Page 1: ...PSDC 16128 v 1 3 PSDC 12V 8A 16x0 5A Power supply for up to 16 HD cameras PTC TOPIC EN Edition 12 from 11 10 2017 Supersedes the edition 11 from 24 04 2017...

Page 2: ...tion surge protection OLP overload protection against tampering warranty 3 year from the production date Example of power supply of up 16 HD cameras All channels adjustable in the range 12V 15V DC 16...

Page 3: ...U The PSU is housed in a metallic enclosure with an indication panel featuring a microswitch indicating unwanted opening of the door faceplate 1 2 Block diagram fig 1 Fig 1 Block diagram of the PSU 1...

Page 4: ...ection connector 2 LED indication of DC power status main module of the PSU 3 PSU module 4 VADJ potentiometer output voltage adjustment within the range of 12V 15V DC 5 LB8 AW A fuse strip with power...

Page 5: ...B outputs indicating fuse failure blow of LB8 AW strips A B SCP activation OC type 50mA max normal status L level 0V failure hi Z level F1 F8 fuses strips A B F 0 5A 250V or PTC 0 5A manual selection...

Page 6: ...in a selected location and connect the wires 3 Connect the power cables 230VAC to L N terminals of the PSU Connect the ground wire to the terminal marked by the earth symbol Use a three core cable wit...

Page 7: ...cated by the LFPS red diode Fig 5 Electrical diagram of the OC output TAMPER output indicating unwanted opening of the PSU contains volt free potential free contacts indicating the door status unit cl...

Page 8: ...ificant dust level clean its interior with compressed air In case of a fuse exchange use the replacement of the same parameters WEEE MARKING According to the EU WEE Directive It is required not to dis...

Reviews: