Pulsar PSDC 04124 Quick Start Manual Download Page 2

www.pulsar.pl 

 

 

 

 

PSDC04124 

 

 

 

 

 
 

2

Features: 

 

 

the

 4x1A/12V DC power output for powering           

4 HD cameras

 

 

output voltage adjustment 12V÷15V DC 

 

4 outputs protected with 1A fuses  

 

jumper selectable fuses: glass fuse or polymer 
fuse 

 

wide range of supply voltage 85÷264V AC  

 

high efficiency 80% 

     LED indication 

 

  FPS technical output of fuse activation 

indication 

  protections: 

 

SCP short-circuit protection 

 

OVP over voltage protection 

 

surge protection  

 

OLP overload protection 

 

against tampering 

  warranty – 3 year from the production date 

 

Example of power supply of up 4 HD cameras. 

 

 

 

All channels adjustable in the range 12V÷15V DC, 4 x 1A 

 

 
 
CONTENTS: 
1. Technical description. 

1.1 General description 
1.2 Block diagram 
1.3 Description of PSU components and connectors 
1.4 Specifications 

2. Installation. 

2.1 Requirements 
2.2 Installation procedure 

3. Operating status indication. 

3.1 LED indication  
3.2 Technical outputs

 

4. Operation and use. 

4.1 Overload or short circuit at the PSU output  
4.2 Maintenance 

  

 

 

 
 
 
 
 
 
 
 
 

Summary of Contents for PSDC 04124

Page 1: ...PSDC 04124 v 1 3 PSDC 12V 4A 4x1A Power supply for up to 4 HD cameras PTC TOPIC EN Edition 12 from 11 10 2017 Supersedes the edition 11 from 24 04 2017...

Page 2: ...P over voltage protection surge protection OLP overload protection against tampering warranty 3 year from the production date Example of power supply of up 4 HD cameras All channels adjustable in the...

Page 3: ...The PSU is housed in a metallic enclosure with an indication panel featuring a microswitch indicating unwanted opening of the door faceplate 1 2 Block diagram fig 1 Fig 1 Block diagram of the PSU 1 3...

Page 4: ...s PE protection connector 2 F fuse in the power supply circuit 230V AC 3 PSU module 4 VADJ potentiometer output voltage adjustment within the range of 12V 15V DC 5 LED indication of DC power status ma...

Page 5: ...se failure blow of LB4 AW strips SCP activation OC type 50mA max normal status L level 0V failure hi Z level F1 F4 fuses F 1A 250V or PTC 1A manual selection Mechanical specifications tab 4 Dimensions...

Page 6: ...PSU in a selected location and connect the wires 3 Connect the power cables 230VAC to L N terminals of the PSU Connect the ground wire to the terminal marked by the earth symbol Use a three core cabl...

Page 7: ...output indicating unwanted opening of the PSU contains volt free potential free contacts indicating the door status unit closed NC unit opened NO 4 Operation and use 4 1 Overload or short circuit at t...

Page 8: ...s required not to dispose of electric or electronic waste as unsorted municipal waste and to collect such WEEE separately Pulsar Siedlec 150 32 744 apczyca Poland Tel 48 14 610 19 40 Fax 48 14 610 19...

Reviews: