1.4 Technical parameters:  

- electrical parameters (tab.3) 
- mechanical parameters (tab.4) 
- operation safety (tab.5) 
- operation parameters (tab.6) 

 
Electrical parameters (tab. 3) 

Supply voltage 

230V/AC  (-15%/+10%) 

Current consumption 

0,39 A max.  

Power frequency 

50Hz 

Supply power 

49 W 

Efficiency 

69% 

Output voltage 

11,0 V÷ 13,8 V DC – buffer operation 
10,0 V÷ 13,8 V DC – battery assisted operation 

Output current 

3,0A + 0,5A battery charging 
2,5A + 1,0A battery charging 

Output voltage setting, escalation and keeping 
time 

20ms / 30ms / 14ms 
 

Voltage adjustment range 

12,0 V÷ 14,5 V  

Ripple voltage 

50 mV p-p max. 

Current consumption by PSU systems 

20 mA – battery assisted operation 

Battery charging current 

0,5A / 1A -  configuration with jumper I

BAT

  

Short-circuit protection SCP  

200% ÷ 250% of supply power - limitation of current and/or fuse 
failure in the battery circuit (fuse-element replacement required) 

Overload protection OLP 

110% ÷ 150% (@25ºC) of power supply - limitation with the PTC  
automatic fuse, manual restart (the fault requires the 
disconnection of the DC output circuit) 

Protection of the battery circuit SCP and reverse 
polarity protection 

5,0 A - current limitation, F

BAT

 fuse (failure requires replace of 

the fuse-element) 

Excessive discharge protection UVP 

U<10,0 V (± 5%) – disconnection of (- BAT) battery, 
configuration with jumper P

BAT

 

Technical outputs: 
- FAC; output indicating failure of AC power supply 
- FPS;  technical output indicating  operation status 
of the power supply 
 
- TAMPER output indicating the power-supply 
casing opening 

 
- OC type, 50mA max. normal status: level L (0V),  failure: level 
hi-Z, 10s time lag. 
- OC type, 50mA max. normal status: level L (0V), failure: level 
hi-Z (automatically recovered after returning correct operation) 
- microswitch, NC contacts (close casing), 0,5A@50V DC (max.) 

F

BAT 

fuse 

F

MAIN 

fuse 

F 5,0A / 250V 
T 0,63A / 250V 

Mechanical parameters (tab. 4). 

Casing dimensions 

235 x 305 x 98  (230 x 300 x 90+8) (WxHxD) [mm] (+/- 2) 

Fixation 

205 x 275 x Φ 6 x4 pcs (WxH) 

Battery space 

17Ah/12V (SLA) max. 

Net/gross weight 

2,90/3,10 kg 

Casing color 

RAL 9003 

Closing 

Cheese screw x 2 (at the front), lock assembly possible 

Connectors 

Power-supply: Φ0,63÷2,50 (AWG 22-10) 
Outputs: Ф0,41÷1,63 (AWG 26-14),  
Battery output BAT: 6,3F-2,5, 30cm,  
TAMPER output: wires, 30cm 

Notes 

The casing is distant from the assembly surface so that cables can be installed 

Operation safety (tab.5). 

Protection class PN-EN 60950-1:2007 

I (first) 

Protection grade PN-EN 60529: 2002 (U) 

IP20 

Electrical strength of insulation: 
- between input (network) circuit and output circuits of power-supply (I/P-O/P) 
- between input circuit and PE protection circuit (I/P-FG) 
- between output circuit and PE protection circuit (O/P-FG) 

 
 
3000 V/AC min. 
1500 V/AC min. 
500  V/AC min. 

Insulation resistance: 
- between input circuit and output or protection circuit 

 
100 MΩ, 500V/DC  

 

Summary of Contents for PSBS 3512C

Page 1: ...PSBS 3512C v 1 0 PSBS 13 8V 3A 17Ah Buffer switch mode power supply unit EN Edition 2 from 16 09 2013 Supercedes the edition 1 from 17 11 2011...

Page 2: ...operation indication 3 1 Optical indication 3 2 Technical output 4 Service and operation 4 1 Overloads or short circuits to the PSU 4 2 Battery assisted operation 4 3 Maintenance 1 Technical descript...

Page 3: ...ry off PBAT protection function disconnection of the battery on Legend dip switch installed dip switch removed 4 VADJ potentiometer voltage adjustment DC 5 Connectors BAT DC supply output of the batte...

Page 4: ...scription 1 Separation transformer 2 Power supply unit board tab 1 fig 2 3 TAMPER microswitches contacts contact of antisabotage protection NC 4 FMAIN witch in the Power supply circuit 230V AC 5 L N p...

Page 5: ...attery configuration with jumper PBAT Technical outputs FAC output indicating failure of AC power supply FPS technical output indicating operation status of the power supply TAMPER output indicating t...

Page 6: ...power supply The earth conductor shall be connected to the terminal marked by the earth symbol PE The connection shall be made by means of a three core cable with a yellow and green PE protection wir...

Page 7: ...ut is shorted to ground state L 0V in case of incorrect operation parameters voltage current temperature the output is switched into hi Z state high impedance TAMPER output indicates opening the power...

Page 8: ...est convenienve however not later that within 14 days from the delivery to the service centre of the manufacturer 6 The repair period mentioned in item 5 may be prolonged if there are no technical pos...

Reviews: