background image

www.pulsar.pl   

 

 

 

PSBS1512B 

 

 

 

 

 
 

 

               WEEE MARK 

 

According to the EU WEE Directive – It is required not to dispose of electric or electronic 

waste as unsorted municipal waste and to collect such WEEE separately.  

 

 
 
 

 

Notice: The power supply unit is adapted for a sealed lead-acid battery (SLA). After the operation period it must 

not be disposed of but recycled according to the applicable law. 

 

 
 
 
 
 
 

 

 

 

 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 

 
 
 
 
 
 
 
 
 
 

GENERAL WARRANTY CONDITIONS 

1. Pulsar K. Bogusz Sp.j. (the manufacturer) grants a two-year warranty for the equipment, starting from the initial product date 
of purchase placed on the receipt.  
2. If a purchase proof is missing, a three-year warranty period is counted from the device’s production date.  
3. The warranty includes free-of-charge repair or replacement with an appropriate equivalent (the selection is at the 
manufacturer’s discretion) if the malfunction is due to the manufacturer, includes manufacturing or material defects, unless such 
defects have been reported within the warranty period (item 1 and 2).  
4. The equipment subject to warranty is to be brought to the place where it was purchased, or directly to the main office of the 
manufacturer.  
5. The warranty applies to complete equipment, accompanied by a properly filled warranty claim with a description of the defect.   
6. Should the claim be accepted, the manufacturer is obliged to provide warranty repairs, at the earliest convenienve, however 
not later that within 14 days from the delivery to the service centre of the manufacturer.  
7. The repair period mentioned in item 6 may be prolonged, if there are no technical possibilities to carry out the repairs, or if the 
equipment has been conditionally accepted, due to the breaking warranty terms by the claimant.  
8. All the services rendered by force of the warranty are carried out at the service centre of the manufacturer, exclusively.  
9. The warranty does not cover the defects of the equipment, resulting from: 
- reasons beyond the manufacturer's control, 
- mechanical damage, 
- improper storage and transport, 
- use that violates the operation manual or equipment’s intended use 
- fortuitous events, including lightning discharges, power failures, fire, flood, high temperatures and chemical agents,  
- improper installation and configuration (in defiance with the manual), 
10. The warranty is void in any of the following circumstances: 
- construction changes  
- repairs carried out by any unauthorized service center 
- damage or removal of warranty labels 
- modifications of the serial number 
11. The liability of the manufacturer towards the buyer is limited to the value of the equipment, determined according to the 
wholesale prices suggested by the manufacturer on the day of purchase.  
12. The manufacturer takes no reponsibility for the defects that result from:  
- the damaging, malfunctioning or inability to operate the equipment 
- defects that result from using the equipment outside its stated specifications and operating parameters failing to abide by the 
recommendations and requirements contained in the manual, or the use of the equipment.  

 

Pulsar K.Bogusz Sp.j.  

Siedlec 150,  32-744 Łapczyca, Poland 

Tel. (+48) 14-610-19-40, Fax. (+48) 14-610-19-50 

e-mail: 

[email protected]

[email protected]

 

http:// 

www.pulsar.pl

www.zasilacze.pl

 

 

Summary of Contents for PSBS 1512B

Page 1: ...PSBS 1512B v 1 0 PSBS 13 8V 1A 7Ah Buffer switch mode power supply unit EN Edition 1 st from 17 th of November 2011 Supercedes the edition...

Page 2: ...uiring stabilized voltage of 12V DC 15 The PSU provides voltage of 13 8 V DC Current efficiency 1 Output current 1 0A 0 2A battery charging 2 Output current 1 0A 0 5A battery charging Total device cur...

Page 3: ...nd jumper installed jumper removed 2 START button launching from battery 3 VADJ potentiometer voltage adjustment DC 4 FBAT fuse in the battery circuit 5 Connectors BAT DC supply output of the battery...

Page 4: ...Part no Description 1 Isolation transformer 2 Power upply unit board tab 1 fig 2 3 TAMPER microswitches contacts for sabotage protection NC 4 FMAIN fuse in the power supply circuit 230V AC 5 L N conn...

Page 5: ...case of a failure fuse element replacement required Excessive discharge protection UVP U 10 0 V 5 disconnection of BAT battery configuration by the PBAT jumper Technical outputs FAC indicates AC powe...

Page 6: ...U Connect the ground wire to the clip marked by the earth symbol PE Use a three core cable with a yellow and green PE protection wire to make the connection Lead the cables to the appropriate clips th...

Page 7: ...n the output indicate the door status unit closed NC unit opened NO 4 Operation and use 4 1 Overloads or short circuits The AUX output of the PSU is equipped with the PTC polymer fuse protection If th...

Page 8: ...mentioned in item 6 may be prolonged if there are no technical possibilities to carry out the repairs or if the equipment has been conditionally accepted due to the breaking warranty terms by the cla...

Reviews: