4. Battery-assisted operation. 

 

4.1. Running the PSU from the battery. 

 

The PSU has been equipped with two buttons on the pcb board which enable running or disconnecting the 

PSU during battery-assisted operation. 

 

Running the PSU from the battery: press the START button on the main board and hold for 1s. 

 

Disconnecting the PSU from the battery: press the STOP button on the main board and hold for 5s. 

 
 

4.2. Deep discharge battery protection UVP. 

The PSU is equipped with the  disconnection system and the discharged  battery indication. If the voltage at 

the  battery  terminals  drops  below  10V±0.2V  during  battery-assisted  operation,  the  battery  will  be  disconnected 
after appr.15s.  

Switching off/on the function of the battery protection: 
Press the ‘SET’ button from the level of the LCD desktop and then choose:  

”PSU -> Battery protection: YES/NO”

 (see chapter 3.4.2, table 7). 

 

Caution. 
Deactivating of the UVP function is not recommended since a deep discharge of the battery limits its 
capability of storing energy, lowers its capacity and shortens its durability. 
 
 

 

4.3 Dynamic battery test. 

The PSU runs a battery test every 10 minutes. It is done by a  momentary switching into a  battery-assisted 

operation. A failure is indicated when voltage drops below 12V. The battery test facility can be switched off. 

 

Deactivating/activating the test:  
- enter the PSU settings from the level of the LCD desktop by pressing the ‘SET’ button. Then choose:  

                          ”PSU -> Battery protection: YES/NO”

 (see chapter 3.4.2, table 7) or 

              - from the pcb level: during  mains-powered PSU operation press the STOP button on the main board and      
hold it for 3 seconds. 

The  device  will  confirm  the  activation/deactivation  of  the  test  (see  tab.8  [6,  7])  and  show  an  appropriate 

message on the display: 

”TEST ON/ TEST OFF”

 

 
Deactivating/activating  the  test  is  stored  in  the  memory  even  after  unplugging  the  device  from 
mains.  The  battery  failure  indication  at  the  APS  FLT  output  is  automatically  switched  off.  The 
battery protection system against deep discharged remains on, though.  
 

 
 

4.4. Standby time.  
The  standby  time  during  batter-assisted  operation  depends  on:  battery  capacity,  battery charge  level  and 

load current. In order to keep the standby time, the current  drawn from the PSU  during  battery-assisted operation 
should be limited. Characteristics for a 17Ah/12V SLA: 

 
Grade 1, 2 - standby time 12h   

 

 

 

 

Output current 1,4A + 3A battery charge 

 
Grade 3 - standby time 30h if the faults of the main power source are reported to the Alarm Receiving 
Centre - ARC (in accordance with 9.2 – PN-EN 50131-1). 
 

 

 

Output current 0,56A + 3A battery charge 

 

 
 - standby time 60h if the faults of the main power source are reported to the Alarm Receiving 

Centre - ARC (in accordance with 9.2 – PN-EN 50131-1). 
 

 

 

Output current 0,28A + 3A battery charge 

 
 
 
 
 
 

Summary of Contents for PSBEN 10A12C/LCD

Page 1: ...PSBEN 10A12C LCD v 1 0 PSBEN 13 8V 10A 17Ah EN LCD Buffer switched mode power supply unit EN Edition 3 from 20 11 2012 Supersedes the 2 from 14 09 2012 edition...

Page 2: ...tting the EPS output lag 17 Setting the communication address 18 3 4 3 Desktop 18 Setting the language of messages 19 Setting the date 19 Setting the time 20 Setting the highlighting 20 Setting the co...

Page 3: ...EQUIREMENTS 30 7 2 INSTALLATION PROCEDURE 30 8 OPERATION AND USE 31 8 1 OVER VOLTAGE PROTECTION OVP AT THE PSU OUTPUT 31 8 2 OVERLOAD OF THE PSU 31 8 3 SHORT CIRCUIT AT THE PSU OUTPUT 31 8 4 BATTERY R...

Page 4: ...history real time clock battery backed optical indication of PSU overload OVL acoustic indication of failure adjustable times indicating AC power failure technical inputs outputs with galvanic isolat...

Page 5: ...ource are reported to the Alarm Receiving Centre ARC in accordance with 9 2 PN EN 50131 1 Output voltage 0 28A 3A battery charge General use if the PSU is not mounted within an installation which is P...

Page 6: ...ion on indication off Caption jumper on jumper off 6 VADJ potentiometer DC voltage adjustment 7 BUZZER acoustic indicator 8 FBAT fuse in the battery circuit 9 Connectors AC AC power input BAT DC power...

Page 7: ...ement no Description 1 Insolation transformer 2 PSU board tab 1 fig 2 3 TAMPER micro switch contacts of tamper resistance NC 4 FMAIN fuse in the supply circuit 230 V AC 5 L N 230V AC power connector P...

Page 8: ...atus indication 3 1 Control panel The PSU is equipped with a panel with buttons and an LCD display which enables reading all available parameters of the device The buttons are for selecting and approv...

Page 9: ...lay The main screen of the LCD display shows basic electrical parameters and informs about the current PSU state Fig 5 The main screen Table 4 Description of the symbols on the main screen Screen fiel...

Page 10: ...status during operation Highlighting of an element informs about an active state and reflects the status of LEDs on the pcb of the PSU see table 1 12 Fig 7 Screen parameters of the PSU Table 5 Descrip...

Page 11: ...analysis of the values shown on the chart the time range of the chart screen can be adjusted in the bottom axis Here are the available ranges 8h 24h 2days week weekly In order to change the displayed...

Page 12: ...erates 3 levels of access to configuration which limit the possibility of changing the PSU s settings from the level of the LCD desktop They are protected with separate passwords Keypad password locks...

Page 13: ...ear with or choose the right level of the password confirm your choice with the SET button with or enter the first digit confirm your choice with the SET button with or enter the second digit confirm...

Page 14: ...sswords have been lost there is a procedure that will allow reassigning the passwords Please do as follows a unplug the PSU from the AC network and the battery for at least 10 seconds b press the STOP...

Page 15: ...to the PSU NO battery not connected to the PSU see chapter 4 6 Battery test YES battery test on NO battery test off see chapter 4 3 Battery protection YES battery protection function disconnection on...

Page 16: ...onfirm your choice with the SET button Setting the battery test with or choose the Battery test menu press the SET button you will see the prompt at the end of the line with or set YES or NO YES batte...

Page 17: ...nction disconnection on NO battery protection function disconnection off confirm your choice with the SET button Setting the EPS output lag with or choose the EPS output lag menu press the SET button...

Page 18: ...mputer confirm your choice with the SET button 3 4 3 Desktop The facility is only available after entering the correct user s or installer s password The Desktop menu enables setting the current date...

Page 19: ...you will see the prompt at the end of the line with or choose the language of messages confirm your choice with the SET button Setting the date with or choose the Date menu press the SET button the pr...

Page 20: ...section with or set the minutes press the SET button the prompt will move to the second section with or set the seconds approve the settings with the SET button Setting the highlighting Intensity of t...

Page 21: ...xt to the constant option with or change the setting into 60 s press the SET button the prompt will move to the end of the line with or set the demanded screen brightness approve your choice with the...

Page 22: ...e In case of a power failure the PSU will switch the output into the open state after a period of time determined by the EPS output lag facility see 3 4 2 table 7 APS FLT output indicating battery fai...

Page 23: ...IN technical input has been implemented with galvanic isolation between the PSU s systems and the devices attached Fig 16 Electrical diagram of the EXT IN input The electrical diagram below shows the...

Page 24: ...attery test facility can be switched off Deactivating activating the test enter the PSU settings from the level of the LCD desktop by pressing the SET button Then choose PSU Battery protection YES NO...

Page 25: ...3 7h 2 2 J1 J2 J3 10h12m 1 5 J1 J2 J3 25h30m 0 6 J1 J2 J3 4 6 Operation without a battery In case of an expected PSU operation without an attached battery make a necessary configuration setting from t...

Page 26: ...tage of wireless communication is lack of additional cords and fast development or modification of the network s structure Fig 19 WI FI communication with the use of the WI FI INTW interface 5 2 Commu...

Page 27: ...USB TTL INTU needs to be used This interface allows direct connection between the computer and the PSU and it is recognisable by the operating system as a virtual COM port Fig 22 USB TTL communicatio...

Page 28: ...attery charge Io 9 1A 1 5A battery charge Io 8 4A 2 2A battery charge Io 7 6A 3A battery charge Output voltage setting escalation and keeping time 8ms 3ms 25ms Output voltage adjustment range 12 V 14...

Page 29: ...losure does not adjoin the assembly surface so that cables can be led Convectional cooling Table 12 Operation safety Protection class PN EN 60950 1 2007 I first Protection grade PN EN 60529 2002 U IP2...

Page 30: ...3 7 and guarantees indication in case of any attempts of detaching the device from the mounting surface Proper installation is one of the requirements of the PN EN 50131 6 standard Fig 24 Fixing a ta...

Page 31: ...output status change opening state acoustie and appropriate message on the PSU front panel 8 2 Overload of the PSU The PSU has been equipped with a LED OVL overload indicator light on the pcb It info...

Page 32: ...high output voltage Output voltage 14 7V F07 ON 2 flashes ON PSU FLT Too high battery voltage Battery voltage 14V F08 ON 3 flashes ON PSU FLT Battery charging circuit failure Too low output voltage of...

Page 33: ...ssibilities to carry out the repairs or if the equipment has been conditionally accepted due to the breaking warranty terms by the claimant 7 All the services rendered by force of the warranty are car...

Reviews: