Overvoltage protection OVP 

55

÷65V DC 

Surge protection 

varistors 

Antisabotage protection: 
- TAMPER output indicating enclosure opening 

 
- microswitch, NC contacts (enclosure closed), 
0,5A@50V DC (max.) 

Optical indication of operation: 

YES 

– LED lights  

       
      

Mechanical parameters (Table 4). 

Enclosure dimensions 

270 x 316 x 101+15 (WxHxD) [mm]  (+/-2) 

Mounting 

See Fig. 3 

Net weight 

3,2kg / 3,5kg 

Enclosure 

DC01 steel plate, 1,0mm, RAL 9003 

Closing 

Cylindrical screw x 1 (at the front) lock assembly possible 

Terminals 

Switch mode power supply: 

Φ0,63-2,05 (AWG 22-12) 

PoE module: Φ0,5-2,05 (AWG 24-12) 
LAN1 

÷ LAN4 inputs: RJ45 8P8C, shielded 

PoE1 

÷ PoE4 outputs: RJ45 8P8C, shielded 

TAMPER output: wires 35cm 

Notes 

The enclosure has a 15mm distance from the mounting surface so the cables 
can be led. PSU cooling: fan cooling. 

      

Safety of use (Table 5). 

Protection class PN-EN 60950-1:2007 

I (first) 

Protection grade PN-EN 60529: 2002 (U) 

IP20 

Insulation electrical strength: 
- between input (network) circuit and the output circuits of the PSU (I/P-O/P) 
- between input circuit and PE protection circuit  (I/P-FG) 
- between output circuit and PE protection circuit (O/P-FG) 

 
3000 V/AC min. 
1500 V/AC min. 
  500 V/AC min. 

Insulation resistance: 
- between input circuit and output or protection circuit 

 
100 MΩ, 500V/DC  

Operation parameters (Table 6). 

Operating temperature 

-

10ºC...+40ºC  

Storing temperature 

-

20ºC...+60ºC 

Relative humidity  

20%...90%, no condensation 

Vibrations during operation  

unacceptable 

Surges during operation 

unacceptable 

Direct insolation 

unacceptable 

Vibrations and surges during transport 

According to the PN-83/T-42106 standard 

 

2.  Installation. 
 

2.1. Requirements. 

The  buffer  PSU  should  be  mounted  by  a  qualified  installer,  holding  relevant  permits  and  licenses 

(applicable and  required  for  a  given  country)  for  230V/AC  and  low-voltage  installations. The  unit  should  be 
mounted  in  confined  spaces,  in  accordance  with  the  2nd environmental  class,  with  normal  relative  humidity 
(RH=90% maximum, no condensation) and temperature range from -

10°C up to +40°C. The  power  supply  should  

operate  in  a  vertical position in order to provide free and  convectional  air  flow  through ventilating holes of the 
enclosure.  

 
 

During normal operation, the total current drawn by the device should not exceed I=2,8A.  

 
The  power  supply  is  designed  for  a  continuous  operation  and  is  not  equipped  with  

a    power-switch.  Therefore,  an  appropriate  overload  protection  in  the  power  supply  circuit  should  be  provided. 
Moreover, the user should be informed how to disconnect the power supply unit from the mains supply (usually by 
assigning an appropriate fuse in the fuse box).   The electrical system shall be made in accordance with applicable 
standards and regulations.  

The PSU is designed for 10Mbit/s and 100Mbit/s  Ethernet network (so-called Fast Ethernet)

. However, it 

can  not  be  used  for  a  1000  Mbit/s  network  (so-called  Gigabit  Ethernet).

  Connections  between  the  power 

supply and the camera can be done using UTP-3 cable (networks with data-rates up to 10 Mbit/s) or UTP-5 cable. 
Due to the lower resistance wiring, it is recommended (especially at large distances between the power supply and 
receivers) to use UTP-5 cable also for networks with data-rates up to 10 Mbit/s.  

 

Summary of Contents for POE0848

Page 1: ...POE0848 v 1 0 PoE 48V 3A PoE power supply for up to 8 IP cameras EN Edition 1 from 09 02 2016 Supersedes the edition...

Page 2: ...ection OLP overload protection warranty 2 year from the production date Example of power supply of up 8 IP cameras range 46V 52V DC 8 x 0 35A TABLE OF CONTENTS 1 Technical description 1 1 General desc...

Page 3: ...ening front cover The PSU can not be used in Gigabit Ethernet networks where all twisted pairs are involved in the transmission of data 1 2 Block diagram Fig 1 Block diagram of the PSU 1 3 The descrip...

Page 4: ...on NC Tab 2 Components of the PSU see Fig 3 1 4 Technical parameters electrical parameters Table 3 mechanical parameters Table 4 safety of use Table 5 operation parameters Table 6 Electrical parameter...

Page 5: ...nacceptable Vibrations and surges during transport According to the PN 83 T 42106 standard 2 Installation 2 1 Requirements The buffer PSU should be mounted by a qualified installer holding relevant pe...

Page 6: ...m is shown in Figure 4 Fig 4 Connection of cameras and network devices to the LAN and PoE terminals 5 In case of significant voltage drops on the receivers power cables resistance it is possible to ad...

Page 7: ...rer 6 The repair period mentioned in point 5 may be prolonged if there are no technical possibilities to carry out the repairs or if the equipment has been conditionally accepted due to the breaking w...

Page 8: ...www pulsar pl POE0848 8 Pulsar Siedlec 150 32 744 apczyca Poland Tel 48 14 610 19 40 Fax 48 14 610 19 50 E mail biuro pulsar pl sales pulsar pl http www pulsar pl www zasilacze pl...

Reviews: