![Pulsar PG4500iSR Operator'S Manual Download Page 9](http://html1.mh-extra.com/html/pulsar/pg4500isr/pg4500isr_operators-manual_1624635009.webp)
9
CONTROL PANEL FUNCTIONS
Oil Warning
Indicator
light
Overload
Indicator
light
AC Pilot
Indicator
light
DC Circuit Breaker
When the DC Circuit Breaker is in the “I” position, the generator is able to supply power to connected electrical devices.
When the DC Circuit Breaker shifts to the "O" position, the generator will no longer supply power. The DC Circuit
Breaker automatically shifts to the "O" position when connecting electrical devices to the generator that exceed the
generator’s rated DC output. If the DC Circuit Breaker shifts to the "O" position , reduce the load of connected electrical
device until the load is within rated DC output. To re-establish power, shift breaker to the "I" position.
CAUTION!
If the DC Circuit Breaker shifts to the "O" position, stop using the generator immediately and consult
Engine Economy Control
• When the engine economy switch is in the “ON” position, the economy control unit automatically determines the
generator’s proper engine speed based on the connected electrical load
.
This results in superior fuel economy
and reduces noise.
• When the economy switch is in the “OFF” position, the engine will maintain a nominal speed of of 3,100 r/min.
AC Pilot Indicator Light
The green AC Pilot Indicator Light comes on when the engine starts and generates power.
1. Disconnect any electrical devices then stop the engine.
2. Reduce the total wattage of connected electrical devices until it is within the generator’s rated output.
3. Inspect the Air Inlet and Control Panel for any blockage. Remove blockage if found.
4. Restart Engine.
How to Correct
a qualified electrician or small engine repair shop.
Summary of Contents for PG4500iSR
Page 25: ...WIRING DIAGRAM 25...
Page 50: ...DIAGRAMA DE CABLEADO 25...